Geographic miss -: A cause of treatment failure in radio-oncology applied to intracoronary radiation therapy

被引:137
作者
Sabaté, M
Costa, MA
Kozuma, K
Kay, IP
van der Giessen, WJ
Coen, VLMA
Ligthart, JMR
Serrano, P
Levendag, PC
Serruys, PW
机构
[1] Erasmus Univ, Acad Ziekenhuis Rotterdam, Heartctr, Dept Intervent Cardiol, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus Univ, Thoraxctr, NL-3000 DR Rotterdam, Netherlands
[3] Acad Ziekenhuis Dijkzigt, Rotterdam, Netherlands
[4] Dr Daniel den Hoed Canc Ctr, NL-3008 AE Rotterdam, Netherlands
关键词
geographic miss; radioisotopes; balloon; angioplasty; stents; angiography; restenosis;
D O I
10.1161/01.CIR.101.21.2467
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-A recognized limitation of endovascular beta-radiation therapy is the development of new stenosis at the edges of the irradiated area. The combination of injury and low-dose radiation may be the precursor of this phenomenon. We translated the radio-oncological concept of "geographic miss" to define cases in which the radiation source did not fully cover the injured area. The aims of the study were to determine the incidence and causes of geographic miss and evaluate the impact of this inadequate treatment on the outcome of patients treated with intracoronary beta-radiation. Methods and Results-We analyzed 50 consecutive patients treated with beta-radiation after percutaneous coronary intervention. The prescribed dose ranged between 12 and 20 Gy at 2 mm from the source axis; By means of quantitative coronary angiography, the irradiated segment (IRS) and both edges were studied before and after intervention and at 6-month follow-up. Edges that were injured during the procedure constituted the geographic miss edges. Twenty-two edges were injured during the intervention, mainly because of procedural complications that extended the treatment beyond the margins of the IRS. Late loss was significantly higher in geographic miss edges than in IRSs and uninjured edges (0.84+/-0.6 versus 0.15+/-0.4 and 0.09+/-0.4 mm, respectively; P<0.0001), Similarly, restenosis rate was significantly higher in the injured edges (10% within IRS, 40.9% in geographic miss edges, and 1.9% in uninjured edges; P<0.001). Conclusions-These data support the hypothesis that the combination of injury and low-dose beta-radiation induces deleterious outcome.
引用
收藏
页码:2467 / 2471
页数:5
相关论文
共 23 条
  • [1] Short- and intermediate-term results of 32P radioactive β-emitting stent implantation in patients with coronary artery disease -: The Milan dose-response study
    Albiero, R
    Adamian, M
    Kobayashi, N
    Amato, A
    Vaghetti, M
    Di Mario, C
    Colombo, A
    [J]. CIRCULATION, 2000, 101 (01) : 18 - 26
  • [2] Dosimetric considerations for catheter-based beta and gamma emitters in the therapy of neointimal hyperplasia in human coronary arteries
    Amols, HI
    Zaider, M
    Weinberger, J
    Ennis, R
    Schiff, PB
    Reinstein, LE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (04): : 913 - 921
  • [3] [Anonymous], 1994, QUANTITATIVE CORONAR
  • [4] Effects of endovascular radiation from a beta-particle-emitting stent in a porcine coronary restenosis model - A dose-response study
    Carter, AJ
    Laird, JR
    Bailey, LR
    Hoopes, TG
    Farb, A
    Fischell, DR
    Fischell, RE
    Fischel, TA
    Virmani, R
    [J]. CIRCULATION, 1996, 94 (10) : 2364 - 2368
  • [5] ANGIOGRAPHIC PREDICTORS OF RECURRENCE OF RESTENOSIS AFTER WIKTOR STENT IMPLANTATION IN NATIVE CORONARY-ARTERIES
    DEJAEGERE, P
    SERRUYS, PW
    BERTRAND, M
    WIEGAND, V
    MARQUIS, JF
    VROLICX, M
    PIESSENS, J
    VALEIX, B
    KOBER, G
    BONNIER, H
    RUTSCH, W
    UEBIS, R
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (02) : 165 - 170
  • [6] CALIBRATION USING ANGIOGRAPHIC CATHETERS AS SCALING DEVICES - IMPORTANCE OF FILMING THE CATHETERS NOT FILLED WITH CONTRAST-MEDIUM
    DIMARIO, C
    HERMANS, WRM
    RENSING, BJ
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (16) : 1377 - 1378
  • [7] QUANTITATIVE ASSESSMENT WITH INTRACORONARY ULTRASOUND OF THE MECHANISMS OF RESTENOSIS AFTER PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY AND DIRECTIONAL CORONARY ATHERECTOMY
    DIMARIO, C
    GIL, R
    CAMENZIND, E
    OZAKI, Y
    VONBIRGELEN, C
    UMANS, V
    DEJAEGERE, P
    DEFEYTER, PJ
    ROELANDT, JRTC
    SERRUYS, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (12) : 772 - 777
  • [8] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [9] EXPERIMENTAL VALIDATION OF GEOMETRIC AND DENSITOMETRIC CORONARY MEASUREMENTS ON THE NEW-GENERATION CARDIOVASCULAR ANGIOGRAPHY ANALYSIS SYSTEM (CAAS-II)
    HAASE, J
    ESCANED, J
    VANSWIJNDREGT, EM
    OZAKI, Y
    GRONENSCHILD, E
    SLAGER, CJ
    SERRUYS, PW
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (02): : 104 - 114
  • [10] HILLSTEAD RA, 1998, HDB VASCULAR BRACHYT, P41