Does the accuracy of single reading with CAD (computer-aided detection) compare with that of double reading?: A review of the literature

被引:17
作者
Bennett, R. L. [1 ]
Blanks, R. G. [1 ]
Moss, S. M. [1 ]
机构
[1] Inst Canc Res, Canc Screening Evaluat Unit, Sutton SM2 5NG, Surrey, England
关键词
D O I
10.1016/j.crad.2006.09.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To examine current evidence to determine whether the accuracy of single reading with computed-aided detection (CAD) compares with that of double reading. METHODS: We performed a literature review to identify studies where both protocols had been investigated and compared. We identified eight studies that compared single reading with CAD against double reading, of which six reported on comparisons of both sensitivity and specificity. RESULTS: Of the six studies identified, three showed no differences in either sensitivity or specificity. One showed single reading with CAD had a higher sensitivity at the same specificity, another that single reading with CAD had a higher specificity at the same sensitivity. However, one study, in a real-life setting, showed that single reading with CAD had a higher sensitivity but a lower specificity. CONCLUSION: As the majority of the studies were not in a real-life setting, used test sets, lacked sufficient training in the use of CAD and simulated double reading (using a protocol of recall if one suggests), current evidence is therefore limited as to the accuracy, in terms of sensitivity and specificity, of single reading with CAD in comparison with the most common practice in the UK of double reading using a protocol of consensus or arbitration. (c) 2006 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1023 / 1028
页数:6
相关论文
共 12 条
[1]   THE EFFICACY OF DOUBLE READING MAMMOGRAMS IN BREAST SCREENING [J].
ANDERSON, EDC ;
MUIR, BB ;
WALSH, JS ;
KIRKPATRICK, AE .
CLINICAL RADIOLOGY, 1994, 49 (04) :248-251
[2]   A comparison of cancer detection rates achieved by breast cancer screening programmes by number of readers, for one and two view mammography: results from the UK National Health Service breast screening programme [J].
Blanks, RG ;
Wallis, MG ;
Moss, SM .
JOURNAL OF MEDICAL SCREENING, 1998, 5 (04) :195-201
[3]   Comparison of standard and double reading and computer-aided detection (CAD) of interval cancers at prior negative screening mammograms: blind review [J].
Ciatto, S ;
Del Turco, MR ;
Burke, P ;
Visioli, C ;
Paci, E ;
Zappa, M .
BRITISH JOURNAL OF CANCER, 2003, 89 (09) :1645-1649
[4]   Comparison of standard reading and computer aided detection (CAD) on a national proficiency test of screening mammography [J].
Ciatto, S ;
Del Turco, MR ;
Risso, G ;
Catarzi, S ;
Bonardi, R ;
Viterbo, V ;
Gnutti, P ;
Guglielmoni, B ;
Pinelli, L ;
Pandiscia, A ;
Navarra, F ;
Lauria, A ;
Palmiero, R ;
Indovina, PL .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (02) :135-138
[5]  
Ciatto Stefano, 2004, Radiol Med, V107, P480
[6]  
Ciatto Stefano, 2003, Radiol Med, V106, P59
[7]   Single reading with computer-aided detection and double reading of screening mammograms in the United Kingdom national breast screening program [J].
Gilbert, Fiona J. ;
Astley, Susan M. ;
McGee, Magnus A. ;
Gillan, Maureen G. C. ;
Boggis, Caroline R. M. ;
Griffiths, Pamela M. ;
Duffy, Stephen W. .
RADIOLOGY, 2006, 241 (01) :47-53
[8]   Computer-aided detection versus independent double reading of masses on mammograms [J].
Karssemeijer, N ;
Otten, JDM ;
Verbeek, ALM ;
Groenewoud, JH ;
de Koning, HJ ;
Hendriks, JHCL ;
Holland, R .
RADIOLOGY, 2003, 227 (01) :192-200
[9]   Computer-aided detection in the United Kingdom National Breast Screening Programme: Prospective study [J].
Khoo, LAL ;
Taylor, P ;
Given-Wilson, RM .
RADIOLOGY, 2005, 237 (02) :444-449
[10]  
*NHS BREAST SCREEN, 2005, QUAL ASS GUID BREAST