EEMCO guidance for the measurement of skin microcirculation

被引:67
作者
Berardesca, E [1 ]
Lévêque, JL [1 ]
Masson, P [1 ]
机构
[1] Univ Pavia, Dept Dermatol, I-27100 Pavia, Italy
来源
SKIN PHARMACOLOGY AND APPLIED SKIN PHYSIOLOGY | 2002年 / 15卷 / 06期
关键词
D O I
10.1159/000066451
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The blood supply to the skin is provided by a network of arterioles, capillaries and venules organized into a superficial and a deep plexus. The assessment of skin microcirculation is of valuable interest in cosmetology in the quantification of the sun protection factor, skin irritation and efficacy of antiredness treatments. Skin microcirculation can be measured by means of different techniques, based mainly on the quantification of optical and thermal properties of the skin which are modified by the amount of blood perfusion. Relevant and reproducible data can be obtained only through the understanding of the biophysical background of the technique(s) utilized. Standardization of measuring conditions and procedures is particularly required for blood flow assessment. In this paper, the advantages and disadvantages of the main techniques in use are discussed, and optimization of measurements for laser Doppler techniques is described. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:442 / 456
页数:15
相关论文
共 62 条
[1]   MEASUREMENT OF COLONIC BLOOD-FLOW WITH LASER DOPPLER FLOWMETRY [J].
AHN, H ;
LINDHAGEN, J ;
LUNDGREN, O .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (07) :871-880
[2]   ASSESSMENT OF BLOOD-FLOW IN THE SMALL-INTESTINE WITH LASER DOPPLER FLOWMETRY [J].
AHN, H ;
LINDHAGEN, J ;
NILSSON, GE ;
OBERG, PA ;
LUNDGREN, O .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (07) :863-870
[3]   EVALUATION OF LASER DOPPLER FLOWMETRY IN THE ASSESSMENT OF INTESTINAL BLOOD-FLOW IN CAT [J].
AHN, H ;
LINDHAGEN, J ;
NILSSON, GE ;
SALERUD, EG ;
JODAL, M ;
LUNDGREN, O .
GASTROENTEROLOGY, 1985, 88 (04) :951-957
[4]   THE OPTICS OF HUMAN-SKIN [J].
ANDERSON, RR ;
PARRISH, JA .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (01) :13-19
[5]   BIOENGINEERING AND THE PATCH TEST [J].
BERARDESCA, E ;
MAIBACH, HI .
CONTACT DERMATITIS, 1988, 18 (01) :3-9
[6]   CUTANEOUS REACTIVE HYPEREMIA - RACIAL-DIFFERENCES INDUCED BY CORTICOID APPLICATION [J].
BERARDESCA, E ;
MAIBACH, H .
BRITISH JOURNAL OF DERMATOLOGY, 1989, 120 (06) :787-794
[7]  
BERNARDI L, 1991, Diabetologia, V34, pA158
[8]   RELATIONSHIP BETWEEN PHASIC CHANGES IN HUMAN-SKIN BLOOD-FLOW AND AUTONOMIC TONE [J].
BERNARDI, L ;
ROSSI, M ;
FRATINO, P ;
FINARDI, G ;
MEVIO, E ;
ORLANDI, C .
MICROVASCULAR RESEARCH, 1989, 37 (01) :16-27
[9]   GUIDELINES FOR MEASUREMENT OF CUTANEOUS BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY - A REPORT FROM THE STANDARDIZATION GROUP OF THE EUROPEAN-SOCIETY-OF-CONTACT-DERMATITIS [J].
BIRCHER, A ;
DEBOER, EM ;
AGNER, T ;
WAHLBERG, JE ;
SERUP, J .
CONTACT DERMATITIS, 1994, 30 (02) :65-72
[10]  
BIRCHER AJ, 1993, AGING SKIN, P105