EEMCO guidance for the measurement of skin microcirculation

被引:67
作者
Berardesca, E [1 ]
Lévêque, JL [1 ]
Masson, P [1 ]
机构
[1] Univ Pavia, Dept Dermatol, I-27100 Pavia, Italy
来源
SKIN PHARMACOLOGY AND APPLIED SKIN PHYSIOLOGY | 2002年 / 15卷 / 06期
关键词
D O I
10.1159/000066451
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
The blood supply to the skin is provided by a network of arterioles, capillaries and venules organized into a superficial and a deep plexus. The assessment of skin microcirculation is of valuable interest in cosmetology in the quantification of the sun protection factor, skin irritation and efficacy of antiredness treatments. Skin microcirculation can be measured by means of different techniques, based mainly on the quantification of optical and thermal properties of the skin which are modified by the amount of blood perfusion. Relevant and reproducible data can be obtained only through the understanding of the biophysical background of the technique(s) utilized. Standardization of measuring conditions and procedures is particularly required for blood flow assessment. In this paper, the advantages and disadvantages of the main techniques in use are discussed, and optimization of measurements for laser Doppler techniques is described. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:442 / 456
页数:15
相关论文
共 62 条
[21]  
FAGRELL B, 1985, J CARDIOVASC PHAR S3, V7, P53
[22]   OBSERVATIONS OF A LASER DOPPLER FLOWMETER OUTPUT MADE USING A CALIBRATION STANDARD [J].
FAIRS, SLE .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1988, 26 (04) :404-406
[23]   INVESTIGATION AND IMPROVED PERFORMANCE OF OPTICAL FIBER PROBES IN LASER DOPPLER BLOOD-FLOW MEASUREMENT [J].
GUSH, RJ ;
KING, TA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (04) :391-396
[24]  
HALE AR, 1960, MEDICINE, V39, P191
[25]   OBSERVATIONS ON A NEW NON-INVASIVE MONITOR OF SKIN BLOOD-FLOW [J].
HALES, JRS ;
STEPHENS, FRN ;
FAWCETT, AA ;
DANIEL, K ;
SHEAHAN, J ;
WESTERMAN, RA ;
JAMES, SB .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1989, 16 (05) :403-415
[26]  
Henry F, 1998, Rev Med Liege, V53, P479
[27]   LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD-FLOW [J].
HOLLOWAY, GA ;
WATKINS, DW .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1977, 69 (03) :306-309
[28]   DIURNAL-VARIATIONS IN TOTAL FOREARM AND SKIN MICROCIRCULATORY BLOOD-FLOW IN MAN [J].
HOUBEN, AJHM ;
SLAAF, DW ;
HUVERS, FC ;
DELEEUW, PW ;
KRUSEMAN, ACN ;
SCHAPER, NC .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1994, 54 (02) :161-168
[29]   NONTHERMOREGULATORY CONTROL OF HUMAN-SKIN BLOOD-FLOW [J].
JOHNSON, JM .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (05) :1613-1622
[30]   LASER-DOPPLER MEASUREMENT OF SKIN BLOOD-FLOW - COMPARISON WITH PLETHYSMOGRAPHY [J].
JOHNSON, JM ;
TAYLOR, WF ;
SHEPHERD, AP ;
PARK, MK .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 56 (03) :798-803