MR imaging of the articular cartilage of the knee with arthroscopy as gold standard: assessment of methodological quality of clinical studies

被引:10
作者
Duchateau, F [1 ]
Vande Berg, BC [1 ]
机构
[1] Catholic Univ Louvain, Clin Univ St Luc, Dept Radiol, B-1200 Brussels, Belgium
关键词
knee; cartilage; MR imaging;
D O I
10.1007/s00330-002-1557-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose of this study was to assess the methodological quality of articles addressing the value of MR imaging of the knee cartilage with arthroscopy as a standard. Relevant papers were selected after Medline review (MEDLINE database search including the terms "cartilage" "knee", "MR" and "arthroscopy"). Two observers reviewed independently 29 selected articles to determine how each study had met 15 individual standards that had been previously developed to assess the methodological quality of clinical investigations. The following criteria were met in variable percentage of articles including adequate definition of purpose (100%), statistical analysis (90%), avoidance of verification bias (86%), patient population description (83%), reference standard (79%), review bias (79%), study design (66%), inclusion criteria (41%) and method of analysis (41.5%), avoidance of diagnostic-review bias (24%), exclusion criteria (21%), indeterminate examination results (17%), analysis criteria (14%), interobserver reliability (14%) and intraobserver reliability (7%). The assessment of the methodological quality of clinical investigations addressing the value of MR imaging in the evaluation of the articular cartilage of the knee with arthroscopy as the standard of reference demonstrated that several standards were rarely met in the literature. Efforts should be made to rely on clearly defined lesion criteria and to determine reliability of the observations.
引用
收藏
页码:2977 / 2981
页数:5
相关论文
共 35 条
[1]
MR IMAGING OF THE KNEE - 3-DIMENSIONAL VOLUME IMAGING COMBINED WITH FAST PROCESSING [J].
ADAM, G ;
BOHNDORF, K ;
DROBNITZKY, M ;
GUENTHER, RW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (06) :984-988
[2]
A scale of methodological quality for clinical studies of radiologic examinations [J].
Arrivé, L ;
Renard, R ;
Carrat, F ;
Belkacem, A ;
Dahan, H ;
Le Hir, P ;
Monnier-Cholley, L ;
Tubiana, JM .
RADIOLOGY, 2000, 217 (01) :69-74
[3]
Degenerative joint disease on MRI and physical activity: a clinical study of the knee joint in 320 patients [J].
Bachmann, GF ;
Basad, E ;
Rauber, K ;
Damian, MS ;
Rau, WS .
EUROPEAN RADIOLOGY, 1999, 9 (01) :145-152
[4]
BLACKBURN WD, 1994, J RHEUMATOL, V21, P675
[5]
Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients [J].
Bredella, MA ;
Tirman, PFJ ;
Peterfy, CG ;
Zarlingo, M ;
Feller, JF ;
Bost, FW ;
Belzer, JP ;
Wischer, TK ;
Genant, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1073-1080
[6]
SEVERITY OF ARTICULAR-CARTILAGE ABNORMALITY IN PATIENTS WITH OSTEOARTHRITIS - EVALUATION WITH FAST SPIN-ECHO MR VS ARTHROSCOPY [J].
BRODERICK, LS ;
TURNER, DA ;
RENFREW, DL ;
SCHNITZER, TJ ;
HUFF, JP ;
HARRIS, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :99-103
[7]
BROWN TR, 1993, SKELETAL RADIOL, V22, P325
[8]
DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY [J].
DISLER, DG ;
MCCAULEY, TR ;
WIRTH, CR ;
FUCHS, MD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :377-382
[9]
Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy [J].
Disler, DG ;
McCauley, TR ;
Kelman, CG ;
Fuchs, MD ;
Ratner, LM ;
Wirth, CR ;
Hospodar, PP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :127-132
[10]
Quantitative MR imaging evaluation of chondropathy in osteoarthritic knees [J].
Drapé, JL ;
Pessis, E ;
Auleley, GR ;
Chevrot, A ;
Dougados, M ;
Ayral, X .
RADIOLOGY, 1998, 208 (01) :49-55