Rapid identification of stabilisers in polypropylene using time-of-flight mass spectrometry and DART as ion source

被引:50
作者
Haunschmidt, Manuela [1 ]
Klampfl, Christian W. [1 ]
Buchberger, Wolfgang [1 ]
Hertsens, Robert [2 ]
机构
[1] Johannes Kepler Univ Linz, Inst Analyt Chem, A-4040 Linz, Austria
[2] Jeol Europe BV, B-1930 Zaventem, Belgium
关键词
ACCELERATED SOLVENT-EXTRACTION; POLYMER ADDITIVES; LIGHT STABILIZER; CHROMATOGRAPHY; QUANTIFICATION; POLYETHYLENE; PRESSURE; POLYOLEFINS; APCI;
D O I
10.1039/b911040b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for analysing plastic samples without any sample pretreatment using direct analysis in real time mass spectrometry (DART-MS) was developed. DART-MS allows the direct, simple and rapid identification of polymer additives in plastic products. To demonstrate the suitability of DART-MS for the detection of a wide range of commonly employed stabilising agents, a test set of 21 stabilisers was selected. In a first step standard solutions of these stabilisers in toluene as well as toluene-extracts from polymer samples were analysed. Subsequently, to prove the applicability of the developed DART-MS method also for the direct analysis of plastic products, samples of polypropylene containing a range of stabilisers were prepared using a lab-scale compounder. Polymer samples were cut into 0.5 cm wide pieces and directly placed into the DART ion source. Focusing on the DART ionisation, several parameters like discharge needle potential, potential of the grid electrode and the discharge electrode, the heater temperature and the gas flow had to be varied to guarantee optimum results. Both positive and negative ionisation was tested, whereby the positive ion mode led to higher signal intensities for all analytes. Determination of accurate masses to improve the certainty in signal assignment could be achieved by using PEG 600 as an internal standard for mass calibration. The developed method allowed the detection of all selected additives (including some of their degradation products) in real polymer samples.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 24 条
[1]  
ALLCOCK HR, 1990, CONT POLYM CHEM, P196
[2]  
Bruheim I, 2000, HRC-J HIGH RES CHROM, V23, P525
[3]   Identification and analysis of polymer additives using packed-column supercritical fluid chromatography with APCI mass spectrometric detection [J].
Carrott, MJ ;
Jones, DC ;
Davidson, G .
ANALYST, 1998, 123 (09) :1827-1833
[4]   Observation of Molecular Ions and Analysis of Nonpolar Compounds with the Direct Analysis in Real Time Ion Source [J].
Cody, Robert B. .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1101-1107
[5]   Identification and quantification of (polymeric) hindered-amine light stabilizers in polymers using pyrolysis-gas chromatography-mass spectrometry and liquid chromatography-ultraviolet absorbance detection-evaporative light scattering detection [J].
Coulier, L ;
Kaal, ER ;
Tienstra, M ;
Hankemeier, T .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1062 (02) :227-238
[6]  
GACHTER R, 1990, TASCHENBUCH KUNSTSTO, P946
[7]   Analysis of additives in polymers by thin-layer chromatography coupled with Fourier transform-infrared microscopy [J].
He, WX ;
Shanks, R ;
Amarasinghe, G .
VIBRATIONAL SPECTROSCOPY, 2002, 30 (02) :147-156
[8]   Determination of polymer additives by liquid chromatography coupled with mass spectrometry. A comparison of atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) [J].
Himmelsbach, Markus ;
Buchberger, Wolfgang ;
Reingruber, Eva .
POLYMER DEGRADATION AND STABILITY, 2009, 94 (08) :1213-1219
[9]   Analysis of polymer additives by matrix-assisted laser desorption ionization/time of flight mass spectrometer using delayed extraction and collision induced dissociation [J].
Hsiao, ST ;
Tseng, MC ;
Chen, YR ;
Her, GR .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2001, 48 (6A) :1017-1027
[10]   Chromatographic methods used to identify and quantify organic polymer additives (Reprinted from Encyclopedia of Chromatography, 2003) [J].
Jenke, D .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (15) :2417-2447