Rapid identification of stabilisers in polypropylene using time-of-flight mass spectrometry and DART as ion source

被引:50
作者
Haunschmidt, Manuela [1 ]
Klampfl, Christian W. [1 ]
Buchberger, Wolfgang [1 ]
Hertsens, Robert [2 ]
机构
[1] Johannes Kepler Univ Linz, Inst Analyt Chem, A-4040 Linz, Austria
[2] Jeol Europe BV, B-1930 Zaventem, Belgium
关键词
ACCELERATED SOLVENT-EXTRACTION; POLYMER ADDITIVES; LIGHT STABILIZER; CHROMATOGRAPHY; QUANTIFICATION; POLYETHYLENE; PRESSURE; POLYOLEFINS; APCI;
D O I
10.1039/b911040b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for analysing plastic samples without any sample pretreatment using direct analysis in real time mass spectrometry (DART-MS) was developed. DART-MS allows the direct, simple and rapid identification of polymer additives in plastic products. To demonstrate the suitability of DART-MS for the detection of a wide range of commonly employed stabilising agents, a test set of 21 stabilisers was selected. In a first step standard solutions of these stabilisers in toluene as well as toluene-extracts from polymer samples were analysed. Subsequently, to prove the applicability of the developed DART-MS method also for the direct analysis of plastic products, samples of polypropylene containing a range of stabilisers were prepared using a lab-scale compounder. Polymer samples were cut into 0.5 cm wide pieces and directly placed into the DART ion source. Focusing on the DART ionisation, several parameters like discharge needle potential, potential of the grid electrode and the discharge electrode, the heater temperature and the gas flow had to be varied to guarantee optimum results. Both positive and negative ionisation was tested, whereby the positive ion mode led to higher signal intensities for all analytes. Determination of accurate masses to improve the certainty in signal assignment could be achieved by using PEG 600 as an internal standard for mass calibration. The developed method allowed the detection of all selected additives (including some of their degradation products) in real polymer samples.
引用
收藏
页码:80 / 85
页数:6
相关论文
共 24 条
[21]   Factors affecting high-pressure solvent extraction (accelerated solvent extraction) of additives from polymers [J].
Vandenburg, HJ ;
Clifford, AA ;
Bartle, KD ;
Zhu, SA ;
Carroll, J ;
Newton, ID ;
Garden, LM .
ANALYTICAL CHEMISTRY, 1998, 70 (09) :1943-1948
[22]   Analytical extraction of additives from polymers [J].
Vandenburg, HJ ;
Clifford, AA ;
Bartle, KD ;
Carroll, J ;
Newton, I ;
Garden, LM ;
Dean, JR ;
Costley, CT .
ANALYST, 1997, 122 (09) :R101-R115
[23]   Accelerated solvent extraction of the antioxidant Irganox 1076 in linear low density polyethylene (LLDPE) granules before and after γ-irradiation [J].
Waldebäck, M ;
Jansson, C ;
Señoráns, FJ ;
Markides, KE .
ANALYST, 1998, 123 (06) :1205-1207
[24]   Selective in situ detection of polymer additives using laser mass spectrometry [J].
Wright, SJ ;
Dale, MJ ;
LangridgeSmith, PRR ;
Zhan, Q ;
Zenobi, R .
ANALYTICAL CHEMISTRY, 1996, 68 (20) :3585-3594