Ribozyme-mediated signal augmentation on a mass-sensitive biosensor

被引:33
作者
Knudsen, Scott M.
Lee, Joonhyung
Ellington, Andrew D.
Savran, Cagri A. [1 ]
机构
[1] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[2] Univ Texas, Dept Chem & Biochem, Austin, TX 78712 USA
关键词
D O I
10.1021/ja064137m
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Mass-based detection methods such as the quartz crystal microbalance (QCM) offer an attractive option to label-based methods; however the sensitivity is generally lower by comparison. In particular, low-molecular-weight analytes can be difficult to detect based on mass addition alone. In this communication, we present the use of effector-dependent ribozymes (aptazymes) as reagents for augmenting small ligand detection on a mass-sensitive device. Two distinct aptazymes were chosen: an L1-ligase-based aptazyme (L1-Rev), which is activated by a small peptide (MW ≈ 2.4 kDa) from the HIV-1 Rev protein, and a hammerhead cleavase-based aptazyme (HH-theo3) activated by theophylline (MW = 180 Da). Aptazyme activity was observed in real time, and low-molecular-weight analyte detection has been successfully demonstrated with both aptazymes. Copyright © 2006 American Chemical Society.
引用
收藏
页码:15936 / 15937
页数:2
相关论文
共 19 条
[1]   Evaluation of antibody immobilization methods for piezoelectric biosensor application [J].
Babacan, S ;
Pivarnik, P ;
Letcher, S ;
Rand, AG .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :615-621
[2]   A piezoelectric quartz crystal biosensor:: The use of two single cysteine mutants of the periplasmic Escherichia coli glucose/galactose receptor as target proteins for the detection of glucose [J].
Carmon, KS ;
Baltus, RE ;
Luck, LA .
BIOCHEMISTRY, 2004, 43 (44) :14249-14256
[3]   Using a deoxyribozyme ligase and rolling circle amplification to detect a non-nucleic acid analyte, ATP [J].
Cho, EJ ;
Yang, LT ;
Levy, M ;
Ellington, AD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2005, 127 (07) :2022-2023
[4]   Development of an immunosensor for human ferritin, a nonspecific tumor marker, based on surface plasmon resonance [J].
Chou, SF ;
Hsu, WL ;
Hwang, JM ;
Chen, CY .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (09) :999-1005
[5]   Detection of small organic analytes by fluorescing molecular switches [J].
Frauendorf, C ;
Jäschke, A .
BIOORGANIC & MEDICINAL CHEMISTRY, 2001, 9 (10) :2521-2524
[6]   Simultaneous detection of diverse analytes with an aptazyme ligase array [J].
Hesselberth, JR ;
Robertson, MP ;
Knudsen, SM ;
Ellington, AD .
ANALYTICAL BIOCHEMISTRY, 2003, 312 (02) :106-112
[7]   Detection of aptamer-protein interactions using QCM and electrochemical indicator methods [J].
Hianik, T ;
Ostatná, V ;
Zajacová, Z ;
Stoikova, E ;
Evtugyn, G .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2005, 15 (02) :291-295
[8]   An aptamer-based quartz crystal protein biosensor [J].
Liss, M ;
Petersen, B ;
Wolf, H ;
Prohaska, E .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4488-4495
[9]   A nanoparticle amplification based quartz crystal microbalance DNA sensor for detection of Escherichia coli O157:H7 [J].
Mao, XL ;
Yang, LJ ;
Su, XL ;
Li, YB .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (07) :1178-1185
[10]   Sensitivity enhancement of surface plasmon resonance biosensing of small molecules [J].
Mitchell, JS ;
Wu, YQ ;
Cook, CJ ;
Main, L .
ANALYTICAL BIOCHEMISTRY, 2005, 343 (01) :125-135