Detecting ventricular fibrillation by time-delay methods

被引:130
作者
Amann, Anton
Tratnig, Robert
Unterkofler, Karl
机构
[1] Vorarlberg Univ Appl Sci, Res Ctr PPE, A-6850 Dornbirn, Austria
[2] Innsbruck Med Univ, Dept Anesthesia & Gen Intens Care, A-6020 Innsbruck, Austria
[3] ETH Zentrum, Dept Environm Sci, CH-8092 Zurich, Switzerland
[4] FH Vorarlberg, Life Sci Biomath Grp, Res Ctr PPE, A-6950 Dornbirn, Austria
关键词
automated external defibrillator (AED); ECG analysis; sinus rhythm (SR); ventricular fibrillation (VF); ventricular fibrillation detection;
D O I
10.1109/TBME.2006.880909
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A pivotal component in automated external defibrillators (AEDs) is the detection of ventricular fibrillation (VF) by means of appropriate detection algorithms. In scientific literature there exists a wide variety of methods and ideas for handling this task. These algorithms should have a high detection quality, be easily implementable, and work in realtime in an AED. Testing of these algorithms should be done by using a large amount of annotated data under equal conditions. For our investigation we simulated a continuous analysis by selecting the data in steps of 1 s without any preselection. We used the complete BIH-MIT arrhythmia database, the CU database, and files 7001-8210 of the AHA database. For a new VF detection algorithm we calculated the sensitivity, specificity, and the area under its receiver operating characteristic curve and compared these values with the results from an earlier investigation of several VF detection algorithms. This new algorithm is based on time-delay methods and outperforms all other investigated algorithms.
引用
收藏
页码:174 / 177
页数:4
相关论文
共 11 条
[1]  
*AM HEART ASS, AHA DAT
[2]  
Amann A, 2005, COMPUT CARDIOL, V32, P559
[3]  
AMANN A, 2005, BIOMED ENG ONLINE, V4
[4]   ALGORITHMIC SEQUENTIAL DECISION-MAKING IN THE FREQUENCY-DOMAIN FOR LIFE THREATENING VENTRICULAR ARRHYTHMIAS AND IMITATIVE ARTIFACTS - A DIAGNOSTIC SYSTEM [J].
BARRO, S ;
RUIZ, R ;
CABELLO, D ;
MIRA, J .
JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (04) :320-328
[5]  
Kerber RE, 1997, CIRCULATION, V95, P1677
[6]  
Kuo S., 1978, Computers in Cardiology 1978, P347
[7]  
*MIT, MIT BIH ARRH DAT
[8]  
*MIT, CU DAT
[9]   VENTRICULAR-TACHYCARDIA AND FIBRILLATION DETECTION BY A SEQUENTIAL HYPOTHESIS-TESTING ALGORITHM [J].
THAKOR, NV ;
ZHU, YS ;
PAN, KY .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (09) :837-843
[10]   Detecting ventricular tachycardia and fibrillation by complexity measure [J].
Zhang, XS ;
Zhu, YS ;
Thakor, NV ;
Wang, ZZ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (05) :548-555