Bad results from good data

被引:43
作者
Badertscher, Martin [1 ]
Pretsch, Erno [1 ]
机构
[1] ETH, Organ Chem Lab, CH-8093 Zurich, Switzerland
关键词
calibration; correlation coefficient; linearization; sensor array; variable selection;
D O I
10.1016/j.trac.2006.09.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This review highlights some common errors of data evaluation that are frequently found in the literature. They include inappropriate choice of the model for fitting calibration curves, and usage of the correlation coefficient and linearization methods. We then question the notion about the advantage of non-selectivity of sensors in an array and highlight the danger of inadequate data-selection methods. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1131 / 1138
页数:8
相关论文
共 24 条
[1]   Cross-validation as the objective function for variable-selection techniques [J].
Baumann, K .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (06) :395-406
[2]   Chance correlation in variable subset regression: Influence of the objective function, the selection mechanism, and ensemble averaging [J].
Baumann, K .
QSAR & COMBINATORIAL SCIENCE, 2005, 24 (09) :1033-1046
[3]   Direct quantification of polymerase chain reaction fragments using field-amplified sample injection in capillary zone electrophoresis for gene dosage estimation [J].
Beckmann, A ;
Gebhardt, F ;
Brandt, BH .
JOURNAL OF CHROMATOGRAPHY B, 1998, 710 (1-2) :75-80
[4]   SPARINGLY SELECTIVE ION-SELECTIVE ELECTRODE ARRAYS FOR MULTICOMPONENT ANALYSIS [J].
BEEBE, K ;
UERZ, D ;
SANDIFER, J ;
KOWALSKI, B .
ANALYTICAL CHEMISTRY, 1988, 60 (01) :66-71
[5]   IMPROVEMENT IN THE DEFINITIONS OF SENSITIVITY AND SELECTIVITY [J].
BERGMANN, G ;
VONOEPEN, B ;
ZINN, P .
ANALYTICAL CHEMISTRY, 1987, 59 (20) :2522-2526
[6]  
Box G, 2005, STAT EXPT INTRO DESI
[7]  
CLERC JT, 1973, CHIMIA, V27, P639
[8]   Multicomponent analysis of heavy metal cations and inorganic anions in liquids by a non-selective chalcogenide glass sensor array [J].
DiNatale, C ;
Davide, F ;
Brunink, JAJ ;
DAmico, A ;
Vlasov, YG ;
Legin, AV ;
Rudnitskaya, AM .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :539-542
[9]  
Exner O, 1997, J PHYS ORG CHEM, V10, P797
[10]   Determination of phosphatidylethanol in blood from alcoholic males using high-performance liquid chromatography and evaporative light scattering or electrospray mass spectrometric detection [J].
Gunnarsson, T ;
Karlsson, A ;
Hanson, P ;
Johnson, G ;
Alling, C ;
Odham, G .
JOURNAL OF CHROMATOGRAPHY B, 1998, 705 (02) :243-249