Measured GFR as a Confirmatory Test for Estimated GFR

被引:454
作者
Stevens, Lesley A. [1 ]
Levey, Andrew S. [1 ]
机构
[1] Tufts Med Ctr, Boston, MA USA
来源
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2009年 / 20卷 / 11期
关键词
GLOMERULAR-FILTRATION-RATE; RENAL PLASMA-FLOW; SERUM CYSTATIN-C; SUBCUTANEOUS INJECTION; NONRADIOACTIVE IOHEXOL; CREATININE CLEARANCE; KIDNEY-FUNCTION; CONTRAST-MEDIA; IOTHALAMATE; SINGLE;
D O I
10.1681/ASN.2009020171
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Clinical assessment of kidney function is central to the practice of medicine. GFR is widely accepted as the best index of kidney function in health and disease, and accurate values are required for optimal decision making. Estimated GFR based on serum creatinine is now widely reported by clinical laboratories, and in most circumstances, estimated GFR is sufficient for clinical decision making. GFR estimates may be inaccurate in the non-steady state and in people in whom non-GFR determinants differ greatly from those in whom the estimating equation was developed. If GFR estimates are likely inaccurate or if decisions based on inaccurate estimates may have adverse consequences, a measured GFR is an important confirmatory test. Endogenous creatinine clearance is the most common method used to measure GFR in clinical practice but may be difficult to obtain or fraught with error. We review methods for GFR measurement using urinary and plasma clearance of exogenous filtration markers and focus on urinary clearance of iothalamate and plasma clearance of iohexol compared with inulin clearance. We suggest plasma clearance of nonradioactive markers be more widely implemented in clinical settings. Further research is necessary on the impact of the use of measured GFR as a confirmatory test.
引用
收藏
页码:2305 / 2313
页数:9
相关论文
共 64 条
[2]   Assessment of Iothalamate Plasma Clearance: Duration of Study Affects Quality of GFR [J].
Agarwal, Rajiv ;
Bills, Jennifer E. ;
Yigazu, Paulos M. ;
Abraham, Terri ;
Gizaw, Andinet B. ;
Light, Robert P. ;
Bekele, Dagim. M. ;
Tegegne, Getachew G. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 (01) :77-85
[3]   IOTHALAMATE SODIUM I 125 VS CYANOCOBALAMIN CO 57 AS A MEASURE OF GLOMERULAR FILTRATION RATE IN MAN [J].
ANDERSON, CF ;
SAWYER, TK ;
CUTLER, RE .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 204 (08) :653-&
[4]   PLASMA AND RENAL CLEARANCE OF IOHEXOL - A STUDY ON THE REPRODUCIBILITY OF A METHOD FOR THE GLOMERULAR-FILTRATION RATE [J].
ARVIDSSON, A ;
HEDMAN, A .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1990, 50 (07) :757-761
[5]  
*BIOPAL INC, 2007, LAB MAN FUNCT IMM TE, P10
[6]  
BROCHNERMORTENSEN J, 1978, DAN MED BULL, V25, P181
[7]   IOHEXOL CLEARANCE FOR THE DETERMINATION OF GLOMERULAR-FILTRATION RATE IN CLINICAL-PRACTICE - EVIDENCE FOR A NEW GOLD STANDARD [J].
BROWN, SCW ;
OREILLY, PH .
JOURNAL OF UROLOGY, 1991, 146 (03) :675-679
[8]  
CHANTLER C, 1969, CLIN SCI, V37, P169
[9]   RENAL RADIOPHARMACEUTICALS - AN UPDATE [J].
CHERVU, LR ;
BLAUFOX, MD .
SEMINARS IN NUCLEAR MEDICINE, 1982, 12 (03) :224-245
[10]   Glomerular filtration rate determination in diabetic patients using iohexol clearance - comparison of single and multiple plasma sampling methods [J].
Chowdhury, TA ;
Dyer, PH ;
Bartlett, WA ;
Legge, ES ;
Durbin, SM ;
Barnett, AH ;
Bain, SC .
CLINICA CHIMICA ACTA, 1998, 277 (02) :153-158