Flow analysis based on a pulsed flow of solution: theory, instrumentation and applications

被引:24
作者
Francis, PS
Lewis, SW [1 ]
Lim, KF
Carlsson, K
Karlberg, B
机构
[1] Deakin Univ, Sch Biol & Chem Sci, Ctr Chiral & Mol Technol, Geelong, Vic 3217, Australia
[2] Stockholm Univ, Dept Analyt Chem, SE-10691 Stockholm, Sweden
关键词
flow analysis; instrumentation; pulsed flow;
D O I
10.1016/S0039-9140(02)00426-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The increased demands placed on solution propulsion by programmed flow systems, such as sequential injection analysis, lab-on-value technology, bead injection and multi-commutation, has highlighted the inability of many conventional pumps to generate a smooth, consistent flow. A number of researchers have examined ways to overcome the inadvertent, uncontrolled pulsation caused by the mechanical aciton of peristaltic pumps. In contrast, we have developed instruments that exploit the characteristics of a reproducible pulsed flow of solution. In this paper, we discuss our instrumental approaches and some applications that have benefited from the use of a reproducible pulsed flow rather than the traditional linear flow approach. To place our approach in the context of the continuously developing field of flow analysis, an overview of other programmed flow systems is also presented. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1029 / 1042
页数:14
相关论文
共 59 条
[1]  
AMPAN P, 2001, 11 ICFIA CHIANG MAI, P46
[2]   MULTICOMMUTATION IN FLOW-ANALYSIS .3. SPECTROPHOTOMETRIC KINETIC DETERMINATION OF CREATININE IN URINE EXPLOITING A NOVEL ZONE SAMPLING APPROACH [J].
ARAUJO, AN ;
LIMA, JLFC ;
REIS, BF ;
ZAGATTO, EAG .
ANALYTICA CHIMICA ACTA, 1995, 310 (03) :447-452
[3]   AUTOMATED TITRATIONS USING A DISCONTINUOUS PROGRAMMED FLOW ANALYZER [J].
ARNOLD, DP ;
PEACHEY, RM ;
PETTY, JD ;
SWEATMAN, DR .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2109-2116
[4]  
BARNETT NW, IN PRESS J AUTOM MET
[5]   Rate measurements by the pulsed-accelerated-flow method [J].
Bowers, CP ;
Fogelman, KD ;
Nagy, JC ;
Ridley, TY ;
Wang, YL ;
Evetts, SW ;
Margerum, DW .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :431-438
[6]   Oscillatory control of sample dispersion in a continuous flow system [J].
Bruno, H ;
Andrade, F ;
Iñón, F ;
Tudino, M ;
Troccolli, O .
ANALYST, 2001, 126 (03) :394-398
[7]   Determination of octanol-water partition coefficients using a micro-volume liquid-liquid flow extraction system [J].
Carlsson, K ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 2000, 423 (01) :137-144
[8]   Micro-continuous flow system for wet chemical analysis [J].
Carlsson, K ;
Jacobsen, HS ;
Jensen, AL ;
Stenstrom, T ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1997, 354 (1-3) :35-42
[9]   Monosegmented micro-volume liquid-liquid flow-extraction system based on intermittent pumping and spectroscopic detection [J].
Carlsson, K ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) :1-7
[10]   The miniaturisation of the standard method based on the N,N′-diethyl-p-phenylenediamine (DPD) reagent for the determination of free or combined chlorine [J].
Carlsson, K ;
Moberg, L ;
Karlberg, B .
WATER RESEARCH, 1999, 33 (02) :375-380