Sellar repair in endoscopic endonasal transsphenoidal surgery: Results of 170 cases

被引:135
作者
Cappabianca, P
Cavallo, LM
Esposito, F
Valente, V
de Divitiis, E
机构
[1] Univ Naples Federico II, Div Neurosurg, Dept Neurol Sci, I-80131 Naples, Italy
[2] Osped Civile Annunziata, Div Neurosurg, Cosenza, Italy
关键词
endoscopy; pituitary adenoma; transsphenoidal surgery;
D O I
10.1227/01.NEU.0000035904.77559.9F
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To describe techniques and materials used in sellar repair after an endoscopic endonasal transsphenoidal approach. Methods: Different techniques of sellar closure and indications for each specific condition are reviewed in a series of 170 consecutive patients. Results: Only 47 (27.6%) of 170 patients were considered candidates for sellar reconstruction after the endoscopic operation, mainly because of intraoperative cerebrospinal fluid leaks (14.1%). The overall rate of postoperative cerebrospinal fluid leakage was 2.3%, which was cured by means of an early reoperation in three cases and with lumbar drainage in the fourth case. Conclusion: Reconstruction of the sella was considered necessary in only one-third of the patients who underwent operations via an endoscopic transsphenoidal procedure. Some minor expedients can be useful for the reconstruction, and the ideal material for the repair should be chosen.
引用
收藏
页码:1365 / 1371
页数:7
相关论文
共 35 条
[21]   Long-term evaluation of reconstruction of the sellar floor with a silicone plate in transsphenoidal surgery [J].
Kabuto, M ;
Kubota, T ;
Kobayashi, H ;
Takeuchi, H ;
Nakagawa, T ;
Kitai, R ;
Kodera, T ;
Kawai, H ;
Arishima, H .
JOURNAL OF NEUROSURGERY, 1998, 88 (06) :949-953
[22]   Cranial base reconstruction after transsphenoidal surgery with bioabsorbable implants: Technical note [J].
Kaptain, GJ ;
Vincent, DA ;
Laws, ER .
NEUROSURGERY, 2001, 48 (01) :232-233
[23]   RECONSTRUCTION OF THE SELLAR FLOOR DURING TRANS-SPHENOIDAL OPERATIONS USING ALUMINA CERAMIC [J].
KOBAYASHI, S ;
SUGITA, K ;
MATSUO, K ;
INOUE, T .
SURGICAL NEUROLOGY, 1981, 15 (03) :196-197
[24]   USEFULNESS OF CERAMIC IMPLANTS IN NEUROSURGERY [J].
KOBAYASHI, S ;
HARA, H ;
OKUDERA, H ;
TAKEMAE, T ;
SUGITA, K .
NEUROSURGERY, 1987, 21 (05) :751-755
[25]   RECONSTRUCTION OF THE SKULL BASE USING A SILICONE PLATE DURING TRANSSPHENOIDAL SURGERY [J].
KUBOTA, T ;
HAYASHI, M ;
KABUTO, M ;
TAKEUCHI, H ;
FUJI, T ;
OHHASHI, M ;
KITABAYASHI, M .
SURGICAL NEUROLOGY, 1991, 36 (05) :360-364
[26]  
LAWS ER, 1977, CURRENT TECHNIQUES O, P161
[27]   Middle turbinate graft for repair of cerebral spinal fluid leaks [J].
Marks, SC .
AMERICAN JOURNAL OF RHINOLOGY, 1998, 12 (06) :417-419
[28]   SILICONE PLATE-INDUCED GRANULOMA PRESENTING PITUITARY APOPLEXYLIKE SYMPTOMS - CASE-REPORT [J].
MATSUMOTO, K ;
KOHMURA, E ;
TSURUZONO, K ;
MORI, K ;
KAWAMO, K ;
TSUJIMURA, T .
SURGICAL NEUROLOGY, 1995, 43 (02) :166-169
[29]   Endoscope-assisted brain surgery: Part 1 - Evolution, basic concept, and current technique [J].
Perneczky, A ;
Fries, G .
NEUROSURGERY, 1998, 42 (02) :219-224
[30]   Sellar reconstruction with resorbable vicryl patches, gelatin foam, and fibrin glue in transsphenoidal surgery: a 10-year experience with 376 patients [J].
Seiler, RW ;
Mariani, L .
JOURNAL OF NEUROSURGERY, 2000, 93 (05) :762-765