Rapid integrity assessment of rat and human epidermal membranes for in vitro dermal regulatory testing: correlation of electrical resistance with tritiated water permeability

被引:61
作者
Fasano, WJ [1 ]
Manning, LA [1 ]
Green, JW [1 ]
机构
[1] DuPont Co Inc, Haskell Lab Hlth & Environm Sci, Newark, DE 19714 USA
关键词
alternating current; electrical resistance; membrane integrity assessment; triated water permeability coefficient;
D O I
10.1016/S0887-2333(02)00084-X
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
An approach is presented that allows for rapid selection of robust rat and human epidermal membranes for use oil in vitro dermal regulatory studies. Tritiated water (THO) permeability was correlated with electrical resistance (ER) and the results used to propose ER values to judge membrane integrity. Rat and human epidermal membranes were prepared and mounted onto in vitro glass static diffusion cells (0.64 cm(2)) maintained at 32 degreesC. THO permeability coefficients (Kp) were determined and compared with ER measurements. Electrical resistance was also determined for various in vitro cell exposure areas from 0.64 cm(2) to 2.54 cm(2). Our results show that rat epidermal membrane THO Kp values exhibited a lognormal distribution with a median value of 2.76 x 10(-3) cm/h. Human epidermal membrane THO Kp values were best described by a Weibull distribution with a median value of 1.13 x 10(-3) cm/h. The corresponding median electrical resistance measurements were greater than or equal to5.59 kOmega for rat and greater than or equal to23 kOmega for human epidermal membranes. Based on the widely used and accepted single point THO Kp thresholds of 2.5xlo-3 cm/h (rat) and,< 1.5x 10-3 cm/h (human), the corresponding ER values of ≤5.87 x 10(-3) and > 17.1 kOmega were calculated and proposed as acceptable benchmarks for pre-qualifying membranes. In our research exploring the relationship between ER and exposure area we report that an inverse relationship exists between ER and in vitro cell exposure area; as cell area increased, ER decreased. The use of electrical resistance provides a rapid and reliable method for evaluating the integrity of rat and human epidermal membranes for in vitro dermal kinetic testing. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:731 / 740
页数:10
相关论文
共 40 条
[21]   The ECVAM international validation study on in vitro tests for skin corrosivity. 2. Results and evaluation by the management team [J].
Fentem, JH ;
Archer, GEB ;
Balls, M ;
Botham, PA ;
Curren, RD ;
Earl, LK ;
Esdaile, DJ ;
Holzhutter, HG ;
Liebsch, M .
TOXICOLOGY IN VITRO, 1998, 12 (04) :483-524
[22]   Comparison of tissue sources for the skin integrity function test (SIFT) [J].
Heylings, JR ;
Clowes, HM ;
Hughes, L .
TOXICOLOGY IN VITRO, 2001, 15 (4-5) :597-600
[23]   STUDIES ON THE EFFECTS OF APPLIED VOLTAGE AND DURATION ON HUMAN EPIDERMAL MEMBRANE ALTERATION/RECOVERY AND THE RESULTANT EFFECTS UPON IONTOPHORESIS [J].
INADA, H ;
GHANEM, AH ;
HIGUCHI, WI .
PHARMACEUTICAL RESEARCH, 1994, 11 (05) :687-697
[24]   Effects of iontophoresis and electroporation on the stratum corneum -: Review of the biophysical studies [J].
Jadoul, A ;
Bouwstra, J ;
Préat, V .
ADVANCED DRUG DELIVERY REVIEWS, 1999, 35 (01) :89-105
[25]   ELECTRICAL ANALYSIS OF FRESH, EXCISED HUMAN SKIN - A COMPARISON WITH FROZEN SKIN [J].
KASTING, GB ;
BOWMAN, LA .
PHARMACEUTICAL RESEARCH, 1990, 7 (11) :1141-1146
[26]   DC ELECTRICAL-PROPERTIES OF FROZEN, EXCISED HUMAN SKIN [J].
KASTING, GB ;
BOWMAN, LA .
PHARMACEUTICAL RESEARCH, 1990, 7 (02) :134-143
[27]   Electrical resistance and tritiated water permeability as indicators of barrier integrity of in vitro human skin [J].
Lawrence, JN .
TOXICOLOGY IN VITRO, 1997, 11 (03) :241-249
[28]  
Nicander I, 1998, CURR PROBL DERMATOL, V26, P165
[29]  
Nicander I, 1998, Skin Res Technol, V4, P213, DOI 10.1111/j.1600-0846.1998.tb00113.x
[30]   EFFECT OF CURRENT, IONIC-STRENGTH AND TEMPERATURE ON THE ELECTRICAL-PROPERTIES OF SKIN [J].
OH, SY ;
LEUNG, L ;
BOMMANNAN, D ;
GUY, RH ;
POTTS, RO .
JOURNAL OF CONTROLLED RELEASE, 1993, 27 (02) :115-125