Effect of cardiac cycle on ultrasound assessment of endothelial function

被引:11
作者
Chuang, ML [1 ]
Douglas, PS [1 ]
Bisinov, EA [1 ]
Stein, JH [1 ]
机构
[1] Univ Wisconsin, Sch Med, Sect Cardiovasc Med, Atherosclerosis Imaging Res Program, Madison, WI 53792 USA
关键词
brachial artery; endothelial function; ultrasound; vasodilation;
D O I
10.1191/1358863x02vm425oa
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
To investigate the effects of non-ECG-triggered imaging during ultrasound studies of endothelial function, brachial artery diameters were measured throughout the cardiac cycle at rest, during reactive hyperemia, and after administration of nitroglycerin. R-wave-triggered imaging using a 7.5-MHz ultrasound transducer with acquisition every 41.7-66.7 ms was performed in 24 subjects. Cardiac cycle-related variation was computed as the maximum per cent change from the end-diastolic diameter. The range of possible errors in flow-mediated dilation (FMD) and nitroglycerin-mediated vasodilation that may result from ignoring cyclic variations in diameter was determined for each condition. True FMD, true nitroglycerin-mediated vasodilation, and the maximum and minimum values that could be erroneously calculated for FMD if timing was ignored all differed dramatically (p < 0.05). The range of apparent FMD values that could be measured was nearly three times the true FMD value. Ignoring temporal position within the cardiac cycle artifactually increased calculated FMD into the normal range, despite truly impaired FMD. Peak arterial dilation occurred before end-systole and greater baseline vessel compliance was associated with greater FMD. Brachial arterial diameters vary significantly throughout the cardiac cycle. The magnitude of this variation is similar to the arterial dilation induced by reactive hyperemia and nitroglycerin, making ECG-triggered imaging mandatory for accurate and reproducible clinical and research measurements of artery diameters and FMD. Measurement of diameters at end-diastole may be preferred to other time-points in the cardiac cycle.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 16 条
[11]   Need for standardization of noninvasive assessment of vascular endothelial function [J].
Kuvin, JT ;
Patel, AR ;
Karas, RH .
AMERICAN HEART JOURNAL, 2001, 141 (03) :327-328
[12]   Non-invasive measurement of endothelial function: effect on brachial artery dilatation of graded endothelial dependent and independent stimuli [J].
Leeson, P ;
Thorne, S ;
Donald, A ;
Mullen, M ;
Clarkson, P ;
Deanfield, J .
HEART, 1997, 78 (01) :22-27
[13]   Non-invasive measurements of arterial structure and function: repeatability, interrelationships and trial sample size [J].
Liang, YL ;
Teede, H ;
Kotsopoulos, D ;
Shiel, L ;
Cameron, JD ;
Dart, AM ;
McGrath, BP .
CLINICAL SCIENCE, 1998, 95 (06) :669-679
[14]   Study of 227Th in the 226Ra(α,3n) reaction [J].
Manns, J ;
Gröger, J ;
Günther, C ;
Müller, U ;
Weber, T ;
de Boer, J .
EUROPEAN PHYSICAL JOURNAL A, 1998, 3 (03) :263-270
[15]  
SORENSEN KE, 1995, BRIT HEART J, V74, P247
[16]   A comparison of brachial artery flow-mediated vasodilation using upper and lower arm arterial occlusion in subjects with and without coronary risk factors [J].
Vogel, RA ;
Corretti, MC ;
Plotnick, GD .
CLINICAL CARDIOLOGY, 2000, 23 (08) :571-575