Tandem calibration methodology: dual nebulizer sample introduction for ICP-MS

被引:18
作者
Huxter, V [1 ]
Hamier, J [1 ]
Salin, ED [1 ]
机构
[1] McGill Univ, Dept Chem, Montreal, PQ H3A 2K6, Canada
关键词
D O I
10.1039/b110427f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application to inductively coupled plasma mass spectrometry (ICP-MS) of a calibration method called the TCM (tandem calibration method) is described. The TCM involves simultaneous introduction of sample and standard into the plasma by two nebulizers operated in parallel. Figures of merit were determined by comparing the results obtained with those produced using the method of standard additions and external standard calibration was used as a probe of the severity of the matrix effect induced. The test solutions in this study contained Cu, Y, Pt and Pb as analytes and 10 mM Ba and 35 mM Na as matrix effect generators. Classical standard addition verified the validity of the TCM and the two methods were shown to be statistically equivalent. The precision of the results obtained was limited by the noise of the sample introduction device (about 4% RSD on difficult samples versus roughly 1% on clean standards), while the accuracy was only slightly limited by the short and long term stability of the arrangement, typically around 2% relative error. The method was easy to implement on existing equipment, inexpensive and potentially suited to automation.
引用
收藏
页码:71 / 75
页数:5
相关论文
共 18 条
[1]  
ALLEN LA, 1996, FACCS 23 C KANS CIT
[2]   Atomic spectrometry update. Atomic mass spectrometry [J].
Bacon, JR ;
Crain, JS ;
Van Vaeck, L ;
Williams, JG .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (08) :879-915
[3]   SOLID SAMPLING WITH INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY - A SURVEY [J].
BAUMANN, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (12) :907-916
[5]   THE PERFORMANCE OF A LOW CONSUMPTION THERMOSPRAY NEBULIZER FOR SPECIFIC USE IN MICRO-HPLC AND GENERAL USE IN FI WITH ICP-AES DETECTION [J].
ELGERSMA, JW ;
BALKE, J ;
MAESSEN, FJMJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) :1073-1088
[6]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[7]   Tandem calibration methodology: dual nebulizer sample introduction for inductively coupled plasma atomic emission spectrometry [J].
Hamier, J ;
Salin, ED .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (06) :497-505
[8]  
HAMIER J, 1996, 64 C ACFAS MONTR QC
[9]   Atomic spectrometry update. Environmental analysis [J].
Hill, SJ ;
Arowolo, TA ;
Butler, OT ;
Chenery, SRN ;
Cook, JM ;
Cresser, MS ;
Miles, DL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (03) :284-317
[10]   QUANTITATIVE-ANALYSIS OF GLASS USING INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION AND MASS-SPECTROMETRY, LASER MICROANALYSIS INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY AND LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
MOENKEBLANKENBURG, L ;
SCHUMANN, T ;
GUNTHER, D ;
KUSS, HM ;
PAUL, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (02) :251-254