A Robust Two-Dimensional Separation for Top-Down Tandem Mass Spectrometry of the Low-Mass Proteome

被引:74
作者
Lee, Ji Eun [1 ,2 ]
Kellie, John F. [1 ,2 ]
Tran, John C. [1 ,2 ]
Tipton, Jeremiah D. [3 ]
Catherman, Adam D. [1 ,2 ]
Thomas, Haylee M. [1 ,2 ]
Ahlf, Dorothy R. [1 ,2 ]
Durbin, Kenneth R. [1 ,2 ]
Vellaichamy, Adaikkalam [1 ,2 ]
Ntai, Ioanna [1 ,2 ]
Marshall, Alan G. [3 ,4 ]
Kelleher, Neil L. [1 ,2 ]
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
[2] Inst Genom Biol, Urbana, IL USA
[3] Florida State Univ, Ion Cyclotron Resonance Program, Natl High Magnet Field Lab, Tallahassee, FL 32306 USA
[4] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
ION-CYCLOTRON RESONANCE; LARGE RIBOSOMAL-SUBUNIT; HUMAN HISTONE H4; INTACT PROTEINS; LIQUID-CHROMATOGRAPHY; COMPLEX-MIXTURES; ACIDIC PROTEINS; PHOSPHORYLATION; IDENTIFICATION; DISSOCIATION;
D O I
10.1016/j.jasms.2009.08.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For fractionation of intact proteins by molecular weight (MW), a sharply improved two-dimensional (2D) separation is presented to drive reproducible and robust fractionation before top-down mass spectrometry of complex mixtures. The "GELFrEE" (i.e., gel-eluted liquid fraction entrapment electrophoresis) approach is implemented by use of Tris-glycine and Tris-tricine gel systems applied to human cytosolic and nuclear extracts from HeLa S3 cells, to achieve a MW-based fractionation of proteins from 5 to >100 kDa in 1 h. For top-down tandem mass spectroscopy (MS/MS) of the low-mass proteome (5-25 kDa), between 5 and 8 gel-elution (GE) fractions are sampled by nanocapillary-LC-MS/MS with 12 or 14.5 tesla Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers. Single injections give about 40 detectable proteins, about half of which yield automated ProSight identifications. Reproducibility metrics of the system are presented, along with comparative analysis of protein targets in mitotic versus asynchronous cells. We forward this basic 2D approach to facilitate wider implementation of top-down mass spectrometry and a variety of other protein separation and/or characterization approaches. (J Am Soc Mass Spectrom 2009, 20, 2183-2191) (C) 2009 American Society for Mass Spectrometry
引用
收藏
页码:2183 / 2191
页数:9
相关论文
共 39 条
[21]   Combinatorial modification of human histone H4 quantitated by two-dimensional liquid chromatography coupled with top down mass spectrometry [J].
Pesavento, James J. ;
Bullock, Courtney R. ;
LeDuc, Richard D. ;
Mizzen, Craig A. ;
Kelleher, Neil L. .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2008, 283 (22) :14927-14937
[22]   Quantitative analysis of modified proteins and their positional isomers by tandem mass spectrometry: Human histone H4 [J].
Pesavento, James J. ;
Mizzen, Craig A. ;
Kelleher, Neil L. .
ANALYTICAL CHEMISTRY, 2006, 78 (13) :4271-4280
[23]   Proteotyping: Population proteomics of human leukocytes using top down mass spectrometry [J].
Roth, Michael J. ;
Parks, Bryan A. ;
Ferguson, Jonathan T. ;
Boyne, Michael T., II ;
Kelleher, Neil L. .
ANALYTICAL CHEMISTRY, 2008, 80 (08) :2857-2866
[24]   Precise and parallel characterization of coding polymorphisms, alternative splicing, and modifications in human proteins by mass spectrometry [J].
Roth, MJ ;
Forbes, AJ ;
Boyne, MT ;
Kim, YB ;
Robinson, DE ;
Kelleher, NL .
MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (07) :1002-1008
[25]   Tricine-SDS-PAGE [J].
Schaegger, Hermann .
NATURE PROTOCOLS, 2006, 1 (01) :16-22
[26]  
SCHAGGER H, 1987, ANAL BIOCHEM, V166, P379
[27]   High-performance mass spectrometry: Fourier transform ion cyclotron resonance at 14.5 tesla [J].
Schaub, Tanner M. ;
Hendrickson, Christopher L. ;
Horning, Stevan ;
Quinn, John P. ;
Senko, Michael W. ;
Marshall, Alan G. .
ANALYTICAL CHEMISTRY, 2008, 80 (11) :3985-3990
[28]   Proteomic profiling of intact proteins using WAX-RPLC 2-D separations and FTICR mass spectrometry [J].
Sharma, Seema ;
Simpson, David C. ;
Tolic, Nikola ;
Jaitly, Navdeep ;
Mayampurath, Anoop M. ;
Smith, Richard D. ;
Pasa-Tolic, Ljiljana .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (02) :602-610
[29]   Mass spectrometric sequencing of proteins from silver stained polyacrylamide gels [J].
Shevchenko, A ;
Wilm, M ;
Vorm, O ;
Mann, M .
ANALYTICAL CHEMISTRY, 1996, 68 (05) :850-858
[30]   Gel-eluted liquid fraction entrapment electrophoresis: An electrophoretic method for broad molecular weight range proteome separation [J].
Tran, John C. ;
Doucette, Alan A. .
ANALYTICAL CHEMISTRY, 2008, 80 (05) :1568-1573