Porous gold surfaces for biosensor applications

被引:70
作者
van Noort, D [1 ]
Mandenius, CF [1 ]
机构
[1] Linkoping Univ, Dept Phys & Measurement Technol, S-58183 Linkoping, Sweden
关键词
porous gold; ellipsometry; protein adsorption; adsorption models; biosensor;
D O I
10.1016/S0956-5663(00)00061-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The sensitivity of optical biosensors where the detection takes place on a planar gold surface can be improved by making the surface porous. The porosity allows a larger number of ligands per surface area resulting in larger optical shifts when interacting with specifically binding analyte molecules. The porous gold was deposited as a thin layer on a planar gold surface by electrochemical deposition in a solution of tetrachloroaurate and lead acetate. A protein, streptavidin, was adsorbed into the formed porous layer and the time course of the adsorption was monitored by in-situ ellipsometry. When the porous layer was 500 nm in thickness a six-fold increase of the ellipsometric response was obtained compared with a planar gold surface. The dependency of porosity and layer thickness was explained with a mathematical model of the gold/porous gold/protein/solution system. (C) 2000 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:203 / 209
页数:7
相关论文
共 23 条
[1]   OPTICAL-PROPERTIES OF THIN-LAYERS OF BOVINE SERUM-ALBUMIN, GAMMA-GLOBULIN, AND HEMOGLOBIN [J].
ARWIN, H .
APPLIED SPECTROSCOPY, 1986, 40 (03) :313-318
[2]  
Azzam R., 1977, ELLIPSOMETRY POLARIZ
[4]   Porous silicon as the carrier matrix in microstructured enzyme reactors yielding high enzyme activities [J].
Drott, J ;
Lindstrom, K ;
Rosengren, L ;
Laurell, T .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1997, 7 (01) :14-23
[5]   SORTING SINGLE MOLECULES - APPLICATION TO DIAGNOSTICS AND EVOLUTIONARY BIOTECHNOLOGY [J].
EIGEN, M ;
RIGLER, R .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1994, 91 (13) :5740-5747
[6]  
Hecht E., 1982, OPTICS
[7]   Combinatorial chemistry in drug discovery [J].
Hogan, JC .
NATURE BIOTECHNOLOGY, 1997, 15 (04) :328-330
[8]   SELF-ASSEMBLY OF MEDIATOR-MODIFIED ENZYME IN POROUS GOLD-BLACK ELECTRODE FOR BIOSENSING [J].
IMAMURA, M ;
HARUYAMA, T ;
KOBATAKE, E ;
IKARIYAMA, Y ;
AIZAWA, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :113-116
[9]   SURFACE-PLASMON RESONANCE DETECTION AND MULTISPOT SENSING FOR DIRECT MONITORING OF INTERACTIONS INVOLVING LOW-MOLECULAR-WEIGHT ANALYTES AND FOR DETERMINATION OF LOW AFFINITIES [J].
KARLSSON, R ;
STAHLBERG, R .
ANALYTICAL BIOCHEMISTRY, 1995, 228 (02) :274-280
[10]  
LEE SP, 1996, SENSOR ACTUATOR, V1, P80