Demonstration of low flow push-pull perfusion

被引:81
作者
Kottegoda, S [1 ]
Shaik, I [1 ]
Shippy, SA [1 ]
机构
[1] Univ Illinois, Dept Chem, Chicago, IL 60607 USA
关键词
in vivo sampling; laser induced fluorescence; capillary electrophoresis; push-pull perfusion; striatum; glutamate; L-trans-pyrrolidine-2,4-dicarboxylic acid;
D O I
10.1016/S0165-0270(02)00245-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Methods to follow in vivo chemical composition provide information regarding the processes of intercellular communication. There is a need for methods that provide chemical information from small volumes of the central nervous system (CNS) without sacrificing neurochemical recovery. One method that offers potential for providing such information is push-pull perfusion. In this study a low flow push-pull perfusion system is introduced that provides high (70-80%) in vitro recoveries. A concentric probe design is used with a 27-gauge stainless steel outer cannula for saline infusion and an inner fused silica capillary for fluid withdrawal. Flow rates of 10-50 nl/min were reliably generated and were well matched in vitro. Sampling was performed in the striatum of an anesthetized rat generating a 0.5 mul sample every 12 min. Capillary electrophoresis was used to determine glutamate levels in each sample; the basal level was found to be 1.97+0.70 muM. The method described was also demonstrated to deliver L-trans-pyrrolidine-2,4-dicarboxylic acid through the perfusion solution while sampling. Post-sampling histological analysis demonstrates little tissue disturbance to the sampled region. These data provide evidence that low flow push-pull method is a viable alternative for studying neurochemical signaling in the CNS. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 36 条
[1]   Microdialysis in mice for drug delivery research [J].
Boschi, G ;
Scherrmann, JM .
ADVANCED DRUG DELIVERY REVIEWS, 2000, 45 (2-3) :271-281
[2]  
Bruno JP, 1999, REV NEUROSCIENCE, V10, P25
[3]   Self referencing ceramic based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes [J].
Burmeister, JJ ;
Gerhardt, GA .
ANALYTICAL CHEMISTRY, 2001, 73 (05) :1037-1042
[4]   An ultrastructural analysis of tissue surrounding a microdialysis probe [J].
Clapp-Lilly, KL ;
Roberts, RC ;
Duffy, LK ;
Irons, KP ;
Hu, Y ;
Drew, KL .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 90 (02) :129-142
[5]   Quantitative microdialysis of serotonin and norepinephrine: Pharmacological influences on in vivo extraction fraction [J].
Cosford, RJO ;
Vinson, AP ;
Kukoyi, S ;
Justice, JB .
JOURNAL OF NEUROSCIENCE METHODS, 1996, 68 (01) :39-47
[6]   A MINIATURIZED PUSH-PULL CANNULA FOR USE IN CONSCIOUS, UNRESTRAINED ANIMALS [J].
DLUZEN, DE ;
RAMIREZ, VD .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1986, 24 (01) :147-150
[7]  
GADDUM JH, 1961, J PHYSIOL-LONDON, V155, pP1
[8]  
Garris PA, 1997, J NEUROCHEM, V68, P152
[9]  
GIULIAN D, 1989, J NEUROSCI, V9, P4416
[10]   Effects of N-methyl-D-aspartate, kainate or veratridine on extracellular concentrations of free D-serine and L-glutamate in rat striatum: An in vivo microdialysis study [J].
Hashimoto, A ;
Kanda, J ;
Oka, T .
BRAIN RESEARCH BULLETIN, 2000, 53 (03) :347-351