Fabrication and characterization of semicircular detection electrodes for contactless conductivity detector - CE microchips

被引:47
作者
Lee, Chia-Yen
Chen, C. M.
Chang, Guan-Liang
Lin, Che-Hsin
Fu, Lung-Ming
机构
[1] Natl Pingtung Univ Sci & Technol, Dept Mat Engn, Pingtung 91201, Taiwan
[2] Da Yeh Univ, Dept Mech & Automat Engn, Changhua, Taiwan
[3] Natl Cheng Kung Univ, Inst Biomed Engn, Tainan 70101, Taiwan
[4] Natl Sun Yat Sen Univ, Dept Mech & Electromech Engn, Kaohsiung 80424, Taiwan
关键词
lab-on-a-chip; microfabrication; semicircular electrode;
D O I
10.1002/elps.200600113
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study uses simple and reliable microfabrication techniques to fabricate CE biochips, integrating a novel contactless conductivity detector in a miniaturized detection system in a microfluiclic biochip. The off-channel electrodes are deposited around side channels by Au sputtering and patterned using a standard "lift-off" process. A vacuum fusion bonding process is employed to seal the lower substrate containing the microchannels and the electrodes to an upper glass cover plate. The variations in the capacitance between the semicircular detection electrodes in the side channels are measured as different samples and ions pass through the detection region of the CE separation channel. Samples of Rhodamine B, commercial sports drinks, mineral waters, and a red wine, respectively, are mixed in different buffer solutions, separated, and successfully detected using the developed device. The semicircular detection electrodes for the contactless conductivity detector have microscale dimensions and provide a valuable contribution to the realization of the lab-on-a-chip concept.
引用
收藏
页码:5043 / 5050
页数:8
相关论文
共 41 条
[1]   Detection of human immunoglobulin in microchip and conventional capillary electrophoresis with contactless conductivity measurements [J].
Abad-Villar, EM ;
Tanyanyiwa, J ;
Fernández-Abedul, MT ;
Costa-García, A ;
Hauser, PC .
ANALYTICAL CHEMISTRY, 2004, 76 (05) :1282-1288
[2]   Electronic protection methods for conductivity detectors in micro capillary electrophoresis devices [J].
Bastemeijer, J ;
Lubking, W ;
Laugere, F ;
Vellekoop, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3) :98-103
[3]  
da Silva JAF, 1998, ANAL CHEM, V70, P4339
[4]   High-resolution DNA separation in microcapillary electrophoresis chips utilizing double-L injection techniques [J].
Fu, LM ;
Lin, CH .
ELECTROPHORESIS, 2004, 25 (21-22) :3652-3659
[5]   Electrokinetically driven micro flow cytometers with integrated fiber optics for on-line cell/particle detection [J].
Fu, LM ;
Yang, RJ ;
Lin, CH ;
Pan, YJ ;
Lee, GB .
ANALYTICA CHIMICA ACTA, 2004, 507 (01) :163-169
[6]   Numerical analysis and experimental estimation of a low-leakage injection technique for capillary electrophoresis [J].
Fu, LM ;
Lin, CH .
ANALYTICAL CHEMISTRY, 2003, 75 (21) :5790-5796
[7]   Electrokinetic injection techniques in microfluidic chips [J].
Fu, LM ;
Yang, RJ ;
Lee, GB ;
Liu, HH .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :5084-5091
[8]   Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing [J].
Gawad, S ;
Schild, L ;
Renaud, P .
LAB ON A CHIP, 2001, 1 (01) :76-82
[9]  
Guijt RM, 2001, ELECTROPHORESIS, V22, P2537, DOI 10.1002/1522-2683(200107)22:12<2537::AID-ELPS2537>3.0.CO
[10]  
2-C