Formation of chlorinated dioxins and furans in a hazardous-waste-firing industrial boiler

被引:31
作者
Gullett, BK [1 ]
Touati, A
Lee, CW
机构
[1] US EPA, Off Res & Dev, Natl Risk Management Res Lab MD 65, Res Triangle Pk, NC 27711 USA
[2] ARCADIS Geraghty & Miller, Res Triangle Pk, NC 27709 USA
关键词
D O I
10.1021/es991196+
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This research examined the potential for emissions of polychlorinated dibenzodioxin and dibenzofuran (PCDD/F) from industrial boilers that cofire hazardous waste. PCDD/F emissions were sampled from a 732 kW (2.5 x 10(6) Btu/ h), 3-pass, firetube boiler using #2 fuel oil cofired with 2,4-dichlorophenol or 1,2-dichlorobenzene and a copper naphthenate mixture. PCDD/F levels were significantly elevated when improved combustion conditions (reduced carbon monoxide, increased carbon dioxide) followed periods of flame wall-impingement and soot formation/deposition on the boiler tubes. Boiler tube deposits became a sink and source for PCDD/F reactants (copper and chlorine) and PCDD/F, resulting in continued formation and emissions long after waste cofiring ceased. The role of deposits in PCDD/F formation makes emissions dependent on current as well as previous firing conditions, resulting in uncertainty regarding prediction of emissions based solely on the type and rate of cofired hazardous waste.
引用
收藏
页码:2069 / 2074
页数:6
相关论文
共 20 条