Transesophageal echocardiography in rats using an intravascular ultrasound catheter

被引:15
作者
Lu, L
Ko, E
Schwartz, GG
Chou, TM
机构
[1] UNIV CALIF SAN FRANCISCO, DIV CARDIOL, SAN FRANCISCO, CA 94143 USA
[2] UNIV CALIF SAN FRANCISCO, CARDIOVASC RES INST, SAN FRANCISCO, CA 94143 USA
[3] DEPT VET AFFAIRS MED CTR, SAN FRANCISCO, CA 94143 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1997年 / 273卷 / 04期
关键词
transthoracic echocardiography; left ventricle; mass;
D O I
10.1152/ajpheart.1997.273.4.H2078
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
In vivo assessment of cardiac structure and function in small animals is an important experimental goal, but currently available techniques have significant limitations. A commercially available intravascular ultrasound (IVUS) system was adapted to perform transesophageal echocardiography (TEE) in rats. Twelve Sprague-Dawley rats (270-370 g) were anesthetized with intraperitoneal pentobarbital sodium. A 4.3-Fr, 30-MHz or an 8-Fr, 20-MHz IVUS catheter was inserted into the esophagus to obtain long-axis views of the aortic arch, short axis views of the ascending aorta, and long-axis views of the pulmonary artery. A preshaped, 8-Fr, 20-MHz catheter was used to obtain short axis images of the left ventricle (LV) at the midpapillary muscle level, which were used to measure LV diastolic and systolic dimensions (diameters) and to calculate LV mass and fractional shortening. Measurements by TEE were compared with those obtained by transthoracic echocardiography in 6 of 12 rats. Postmortem, the LV was weighed to determine actual LV mass. The correlation coefficients between TEE-and transthoracic echocardiography-calculated LV mass and actual LV mass were 0.94 and 0.88, respectively, and had a good agreement with actual LV mass. Inter-and intraobserver variability of TEE measurements was <10%. IVUS instrumentation may offer an alternative technique for the accurate, serial assessment of LV dimensions, mass, and systolic function and a means of imaging the great vessels in small laboratory animals.
引用
收藏
页码:H2078 / H2082
页数:5
相关论文
共 11 条
[1]
NONINVASIVE ASSESSMENT OF VENTRICULAR DAMAGE IN RATS WITH MYOCARDIAL-INFARCTION [J].
BAILY, RG ;
LEHMAN, JC ;
GUBIN, SS ;
MUSCH, TI .
CARDIOVASCULAR RESEARCH, 1993, 27 (05) :851-855
[2]
Cavaye D M, 1993, Am J Card Imaging, V7, P109
[3]
DESIMONE G, 1990, AM J HYPERTENS, V3, P688
[4]
Gardner T. J., 1988, Experimental surgery and physiology: induced animal models., P74
[5]
Transesophageal echocardiography in fetal sheep - A monitoring tool for open and fetoscopic cardiac procedures [J].
Kohl, T ;
Stelnicki, EJ ;
VanderWall, KJ ;
Szabo, Z ;
Ko, E ;
Bruch, SW ;
Harrison, MR ;
Silverman, NH ;
Hanley, FL ;
Chou, TM .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1996, 10 (08) :820-824
[6]
Experimental fetal transesophageal and intracardiac echocardiography utilizing intravascular ultrasound technology [J].
Kohl, T ;
Szabo, Z ;
VanderWall, KJ ;
Hutchison, SJ ;
Stelnicki, EJ ;
Meuli, M ;
Harrison, MR ;
Silverman, NH ;
Chou, TM .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (10) :899-&
[7]
SERIAL ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR GEOMETRY AND FUNCTION AFTER LARGE MYOCARDIAL-INFARCTION IN THE RAT [J].
LITWIN, SE ;
KATZ, SE ;
MORGAN, JP ;
DOUGLAS, PS .
CIRCULATION, 1994, 89 (01) :345-354
[8]
SERIAL ECHOCARDIOGRAPHIC-DOPPLER ASSESSMENT OF LEFT-VENTRICULAR GEOMETRY AND FUNCTION IN RATS WITH PRESSURE-OVERLOAD HYPERTROPHY - CHRONIC ANGIOTENSIN-CONVERTING ENZYME-INHIBITION ATTENUATES THE TRANSITION TO HEART-FAILURE [J].
LITWIN, SE ;
KATZ, SE ;
WEINBERG, EO ;
LORELL, BH ;
AURIGEMMA, GP ;
DOUGLAS, PS .
CIRCULATION, 1995, 91 (10) :2642-2654
[9]
LU L, 1994, ULTRASOUND MED BIOL, V20, pS121
[10]
CLINICAL-APPLICATIONS OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
MATSUZAKI, M ;
TOMA, Y ;
KUSUKAWA, R .
CIRCULATION, 1990, 82 (03) :709-722