Three dimensional optical angiography

被引:543
作者
Wang, Ruikang K. [1 ]
Jacques, Steven L.
Ma, Zhenhe
Hurst, Sawan
Hanson, Stephen R.
Gruber, Andras
机构
[1] Oregon Hlth & Sci Univ, Dept Biomed Engn, Portland, OR 97239 USA
[2] Oregon Hlth & Sci Univ, Dept Dermatol, Portland, OR 97239 USA
关键词
D O I
10.1364/OE.15.004083
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
With existing optical imaging techniques three-dimensional (3-D) mapping of microvascular perfusion within tissue beds is severely limited by the efficient scattering and absorption of light by tissue. To overcome these limitations we have developed a method of optical angiography (OAG) that can generate 3-D angiograms within millimeter tissue depths by analyzing the endogenous optical scattering signal from an illuminated sample. The technique effectively separates the moving and static scattering elements within tissue to achieve high resolution images of blood flow, mapped into the 3-D optically sectioned tissue beds, at speeds that allow for perfusion assessment in vivo. Its development has its origin in Fourier domain optical coherence tomography. We used OAG to visualize the cerebral microcirculation, of adult living mice through the intact cranium, measurements which would be difficult, if not impossible, with other optical imaging techniques. (c) 2007 Optical Society of America.
引用
收藏
页码:4083 / 4097
页数:15
相关论文
共 41 条
[1]  
[Anonymous], TRANSFORMS APPL HDB
[2]   Heterodyne Fourier domain optical coherence tomography for full range probing with high axial resolution [J].
Bachmann, AH ;
Leitgeb, RA ;
Lasser, T .
OPTICS EXPRESS, 2006, 14 (04) :1487-1496
[3]   PRODUCT THEOREM FOR HILBERT TRANSFORMS [J].
BEDROSIAN, E .
PROCEEDINGS OF THE IEEE, 1963, 51 (05) :868-&
[4]   In vivo cellular optical coherence tomography imaging [J].
Boppart, SA ;
Bouma, BE ;
Pitris, C ;
Southern, JF ;
Brezinski, ME ;
Fujimoto, JG .
NATURE MEDICINE, 1998, 4 (07) :861-865
[5]   Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography [J].
Chen, ZP ;
Milner, TE ;
Srinivas, S ;
Wang, XJ ;
Malekafzali, A ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (14) :1119-1121
[6]   Spectral resolution and sampling issues in Fourier-transform spectral interferometry [J].
Dorrer, C ;
Belabas, N ;
Likforman, JP ;
Joffre, M .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2000, 17 (10) :1795-1802
[7]   Ultrahigh-resolution ophthalmic optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Ghanta, RK ;
Kärtner, FX ;
Schuman, JS ;
Fujimoto, JG .
NATURE MEDICINE, 2001, 7 (04) :502-507
[8]  
Fercher AF, 2003, REP PROG PHYS, V66, P239, DOI 10.2184/lsj.31.635
[9]   High speed spectral domain polarization sensitive optical coherence tomography of the human retina [J].
Götzinger, E ;
Pircher, M ;
Hitzenberger, CK .
OPTICS EXPRESS, 2005, 13 (25) :10217-10229
[10]   High speed full range complex spectral domain optical coherence tomography [J].
Götzinger, E ;
Pircher, M ;
Leitgeb, RA ;
Hitzenberger, CK .
OPTICS EXPRESS, 2005, 13 (02) :583-594