Aluminium junctions as macromolecule detectors and comparison with ionizing detectors

被引:13
作者
Gervasio, G
Gerber, D
Gritti, D
Gonin, Y
Twerenbold, D
Vuilleumier, JL
机构
[1] Univ Neuchatel, Inst Phys, IPH, CH-2000 Neuchatel, Switzerland
[2] GenSpec SA, CH-2017 Boudry, Switzerland
关键词
D O I
10.1016/S0168-9002(99)01412-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cryogenic particle detectors have been proposed as alternative detectors for heavy molecule mass spectrometry [1]. The concept has been demonstrated by various groups in the last 3 years [2-10]. The single-molecule detection efficiency is independent of mass and close to the geometrical beam coverage. In addition, the charged state of the macromolecule can be determined by the pulse height of the cryodetector signal [7]. In this work, we present results from aluminium junctions (50 mu m x 400 mu m) cooled by a dilution refrigerator. The Al-junction detectors were exposed to 6 keV X-rays from a Fe-55 source and to a variety of macromolecules, including IgG and polyethylenglycols (PEGs). Identical samples have been measured with a conventional secondary electron multiplier detector, allowing a sensitivity comparison. Our data, combined with measurements from other groups, suggest that the MALDI extraction does not affect too much the sample mass distribution, and that secondary electron detector sensitivity decreases with decreasing molecule velocity as exp( - (v/v(0))(3.5)) With v(0) being of the order of 50 km/s. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 11 条
[1]  
Benner WH, 1997, J AM SOC MASS SPECTR, V8, P1094
[2]  
Frank M, 1996, RAPID COMMUN MASS SP, V10, P1946, DOI 10.1002/(SICI)1097-0231(199612)10:15<1946::AID-RCM774>3.0.CO
[3]  
2-3
[4]  
Gerber D., 1997, P 7 INT WORKSH LOW T, P73
[5]  
GERBER DR, 1997, THESIS I PHYSIQUE U
[6]  
GROSJEAN CH, 1997, THESIS I PHYSIQUE U
[7]   Impact energy measurement in time-of-flight mass spectrometry with cryogenic microcalorimeters [J].
Hilton, GC ;
Martinis, JM ;
Wollman, DA ;
Irwin, KD ;
Dulcie, LL ;
Gerber, D ;
Gillevet, PM ;
Twerenbold, D .
NATURE, 1998, 391 (6668) :672-675
[8]   Detection of single macromolecules using a cryogenic particle detector coupled to a biopolymer mass spectrometer [J].
Twerenbold, D ;
Vuilleumier, JL ;
Gerber, D ;
Tadsen, A ;
vandenBrandt, B ;
Gillevet, PM .
APPLIED PHYSICS LETTERS, 1996, 68 (24) :3503-3505
[9]   Biopolymer mass spectrometer with cryogenic particle detectors [J].
Twerenbold, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (01) :253-255
[10]   Secondary ion and electron yield measurements for surfaces bombarded with large molecular ions [J].
Westmacott, G ;
Ens, W ;
Standing, KG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1996, 108 (03) :282-289