MR imaging of knee cartilage with FEMR

被引:20
作者
Vasnawala, SS
Pauly, JM
Nishimura, DG
Gold, GE [1 ]
机构
[1] Stanford Univ, Dept Diagnost Radiol, Stanford, CA 94305 USA
[2] Stanford Univ, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
[3] Palo Alto VA Hlth Care Syst, VA Rehabil Res & Dev Sci, Palo Alto, CA 94304 USA
关键词
cartilage; MRI; steady-state; fast; lipid suppression;
D O I
10.1007/s00256-002-0562-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: Fluctuating equilibrium magnetic resonance (FEMR) is a rapid three-dimensional (3D) imaging sequence with high signal-to-noise ratio (SNR). FEMR may be useful for detecting cartilage defects in the knee. At 1.5 T, FEMR uses a TR with odd multiples of 2.2 ms for fat/water separation. With a TR of 6.6 ms, high-resolution 3D imaging of cartilage is possible. Design and patients: The knees of 10 volunteers and two patients were imaged on a GE Signa 1.5 T scanner using an extremity coil. Scans were preceded by a shimming sequence optimizing linear terms. Subjects were imaged with FEMR, proton-density fast spin-echo (PD-FSE), T2-weighted fast spin-echo (T2-FSE), and 3D fat-suppressed spoiled-gradient-recalled echo (3D-SPGR). Results: SNR and contrast-to-noise efficiency measurements for cartilage using FEMR were superior to those using PD-FSE, T2-FSE, and 3D-FS-SPGR. FSE images showed bright synovial fluid with limited cartilage detail. 3D-SPGR had comparable resolution to FEMR but suboptimal cartilage/fluid contrast and longer scan times (9 min versus 2 min). Cartilage surface detail, outlined by bright synovial fluid, was best seen on the FEMR images. Discussion: FEMR obtains high-resolution 3D images of the entire knee in 2 min with excellent cartilage/fluid contrast. FEMR is sensitive to field inhomogeneity and requires shimming. Surface defects are outlined by bright synovial fluid, and cartilage has higher signal-to-noise efficiency compared with PD-FSE, T2-FSE, and 3D-SPGR techniques.
引用
收藏
页码:574 / 580
页数:7
相关论文
共 17 条
[1]   Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients [J].
Bredella, MA ;
Tirman, PFJ ;
Peterfy, CG ;
Zarlingo, M ;
Feller, JF ;
Bost, FW ;
Belzer, JP ;
Wischer, TK ;
Genant, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1073-1080
[2]   MR imaging of articular cartilage [J].
Disler, DG ;
Recht, MP ;
McCauley, TR .
SKELETAL RADIOLOGY, 2000, 29 (07) :367-377
[3]   Fat-suppressed three-dimensional spoiled gradient-recalled MR imaging: Assessment of articular and physeal hyaline cartilage [J].
Disler, DG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) :1117-1123
[4]   Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T [J].
Duerk, JL ;
Lewin, JS ;
Wendt, M ;
Petersilge, C .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :203-208
[5]   Usefulness of turbo spin-echo MR imaging in the evaluation of meniscal tears: Comparison with a conventional spin-echo sequence [J].
Escobedo, EM ;
Hunter, JC ;
ZinkBrody, GC ;
Wilson, AJ ;
Harrison, SD ;
Fisher, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (05) :1223-1227
[6]  
Gold G E, 1998, Top Magn Reson Imaging, V9, P377
[7]   MR imaging of articular cartilage of the knee: New methods using ultrashort TEs [J].
Gold, GE ;
Thedens, D ;
Pauly, JM ;
Fechner, KP ;
Bergman, G ;
Beaulieu, CF ;
Macovski, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1223-1226
[8]   Current status of imaging of articular cartilage [J].
Hodler, J ;
Resnick, D .
SKELETAL RADIOLOGY, 1996, 25 (08) :703-709
[9]  
McCauley T R, 2001, J Am Acad Orthop Surg, V9, P2
[10]  
Recht M P, 1998, Top Magn Reson Imaging, V9, P328