Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method

被引:12
作者
Apostolopoulos, Vasileios [1 ,2 ]
Tomas, Tomas [1 ,2 ]
Bohac, Petr [3 ]
Marcian, Petr [3 ]
Mahdal, Michal [1 ,2 ]
Valousek, Tomas [1 ,2 ]
Janicek, Pavel [1 ,2 ]
Nachtnebl, Lubos [1 ,2 ]
机构
[1] Masaryk Univ, St Annes Univ Hosp, Dept Orthopaed Surg 1, Brno, Czech Republic
[2] Masaryk Univ, Fac Med, Brno, Czech Republic
[3] Brno Univ Technol, Inst Solid Mech Mechatron & Biomech, Fac Mech Engn, Brno, Czech Republic
关键词
Orthopaedic biomechanics; Total knee arthroplasty; Bone mechanics; All-polyethylene tibial component; Finite element model; von Mises strain; SKELETAL STRUCTURAL ADAPTATIONS; MECHANICAL USAGE SATMU; REDEFINING WOLFF LAW; COMPONENTS; FORCES; REVISION;
D O I
10.1016/j.cmpb.2022.106834
中图分类号
TP39 [计算机的应用];
学科分类号
080201 [机械制造及其自动化];
摘要
Background and objective: Total knee arthroplasty (TKA) with modern all-polyethylene tibial (APT) components has shown high long-term survival rates and comparable results to those with metal-backed tibial components. Nevertheless, APT components are primarily recommended for older and low-demand patients. There are no evidence-based biomechanical guidelines for orthopaedic surgeons to determine the appropriate lower age limit for implantation of APT components. A biomechanical analysis was assumed to be suitable to evaluate the clinical results in patients under 70 years. The scope of this study was to determine biomechanically the appropriate lower age limit for implantation of APT components. Methods: To generate data of the highest possible quality, the geometry of the computational models was created based on computed tomography (CT) images of a representative patient. The cortical bone tissue model distinguishes the change in mechanical properties described in three parts from the tibial cut. The cancellous bone material model has a heterogeneous distribution of mechanical properties. The values used to determine the material properties of the tissues were obtained from measurements of a CT dataset comprising 45 patients. Results: Computational modeling showed that in the majority of the periprosthetic volume, the von Mises strain equivalent ranges from 200 to 2700 its; these strain values induce bone modeling and remodeling. The highest measured deformation value was 2910 its. There was no significant difference in the induced mechanical response between bone models of the 60-year and 70-year age groups, and there was < 3% difference from the 65-year age group. Conclusions: Considering in silico limitations, we suggest that APT components could be conveniently used on a bone with mechanical properties of the examined age categories. Under defined loading conditions, implantation of TKA with APT components is expected to induce modeling and remodeling of the periprosthetic tibia. Following clinical validation, the results of our study could modify the indication criteria of the procedure, and lead to more frequent implantation of all-polyethylene TKA in younger patients. (c) 2022 The Authors. Published by Elsevier B.V.This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
引用
收藏
页数:9
相关论文
共 46 条
[1]
Finite -Element analysis of a lateral femoro-tibial impact on the total knee arthroplasty [J].
Arab, Ali Zine El-Abidine ;
Merdji, Ali ;
Benaissa, Ali ;
Roy, Sandipan ;
Bouiadjra, Bel-Abbes Bachir ;
Layadi, Khaled ;
Ouddane, Abdelhakim ;
Mukdadi, Osama M. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 192
[2]
biomet Z., 2016, NexGenCR-Flex and LPS-Flex Knees
[3]
All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty [J].
Brihault, Jean ;
Navacchia, Alessandro ;
Pianigiani, Silvia ;
Labey, Luc ;
De Corte, Ronny ;
Pascale, Valerio ;
Innocenti, Bernardo .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) :2550-2559
[4]
Chamrad J, 2018, Applied and Computational Mechanics, V12, DOI [10.24132/acm.2018.385, 10.24132/acm.2018.385, DOI 10.24132/ACM.2018.385]
[5]
The influence of different tibial stem designs in load sharing and stability at the cement-bone interface in revision TKA [J].
Completo, A. ;
Simoes, J. A. ;
Fonseca, F. ;
Oliveira, M. .
KNEE, 2008, 15 (03) :227-232
[6]
Strain shielding in proximal tibia of stemmed knee prosthesis: Experimental study [J].
Completo, A. ;
Fonseca, F. ;
Simoes, J. A. .
JOURNAL OF BIOMECHANICS, 2008, 41 (03) :560-566
[7]
Revision total knee arthroplasty: The influence of femoral stems in load sharing and stability [J].
Completo, A. ;
Simoes, J. A. ;
Fonseca, F. .
KNEE, 2009, 16 (04) :275-279
[8]
The Role of All-Polyethylene Tibial Components in Modern TKA [J].
Doran, James ;
Yu, Stephen ;
Smith, Daniel ;
Iorio, Richard .
JOURNAL OF KNEE SURGERY, 2015, 28 (05) :382-389
[9]
Dunne N, 2008, ORTHOPAEDIC BONE CEMENTS, P233, DOI 10.1533/9781845695170.3.233
[10]
A multiscale 3D finite element analysis of fluid/solute transport in mechanically loaded bone [J].
Fan, Lixia ;
Pei, Shaopeng ;
Lu, X. Lucas ;
Wang, Liyun .
BONE RESEARCH, 2016, 4