Improved ion extraction from a linear octopole ion trap: SIMION analysis and experimental demonstration

被引:140
作者
Wilcox, BE [1 ]
Hendrickson, CL [1 ]
Marshall, AG [1 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Ion Cyclotron Resonance Program, Dept Chem, Tallahassee, FL 32310 USA
基金
美国国家科学基金会;
关键词
D O I
10.1016/S1044-0305(02)00622-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Externally generated ions are accumulated in a linear octopole ion trap before injection into our 9.4 T Fourier transform ion cyclotron resonance (FT-ICR) mass analyzer. Such instrumental configuration has previously been shown to provide improved sensitivity, scan rate, and duty cycle relative to accumulated trapping in the ICR cell. However, inefficient ion ejection from the octopole currently limits both detection limit and scan rate. SIMION 7.0 analysis predicts that a dc axial electric field inside the linear octopole ion trap expedites and synchronizes the efficient extraction of the octopole-accumulated ions. Further SIMION analysis optimizes the ion ejection properties of each of three electrode configurations designed to produce a near-linear axial potential gradient. More efficient extraction and transfer of accumulated ions spanning a wide m/z range promises to reduce detection limit and increase front-end sampling rate (e.g., to increase front-end resolution for separation techniques coupled with FT-ICR mass analysis). Addition of the axial field improves experimental signal-to-noise ratio by more than an order of magnitude. (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:1304 / 1312
页数:9
相关论文
共 42 条
[11]  
GERLICH D, 1992, ADV CHEM PHYS, V82, P1
[12]   NEW ION-OPTICAL DEVICES UTILIZING OSCILLATORY ELECTRIC-FIELDS .4. COMPUTER-SIMULATIONS OF THE TRANSPORT OF AN ION-BEAM THROUGH AN IDEAL QUADRUPOLE, HEXAPOLE, AND OCTOPOLE OPERATING IN THE RF-ONLY MODE [J].
HAGG, C ;
SZABO, I .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 73 (03) :295-312
[13]   NEW ION-OPTICAL DEVICES UTILIZING OSCILLATORY ELECTRIC-FIELDS .3. STABILITY OF ION MOTION IN A TWO-DIMENSIONAL OCTOPOLE FIELD [J].
HAGG, C ;
SZABO, I .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 73 (03) :277-294
[14]   Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Hendrickson, CL ;
Emmett, MR .
ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1999, 50 :517-536
[15]   A segmented radiofrequency-only quadrupole collision cell for measurements of ion collision cross section on a triple quadrupole mass spectrometer [J].
Javahery, G ;
Thomson, B .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (07) :697-702
[16]   Novel Linac II electrode geometry for creating an axial field in a multipole ion guide [J].
Loboda, A ;
Krutchinsky, A ;
Loboda, O ;
McNabb, J ;
Spicer, V ;
Ens, W ;
Standing, K .
EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2000, 6 (06) :531-536
[17]  
LOBODA AV, 2000, P 48 ASMS C MASS SPE
[18]  
Lock CM, 1999, RAPID COMMUN MASS SP, V13, P432, DOI 10.1002/(SICI)1097-0231(19990315)13:5<432::AID-RCM504>3.0.CO
[19]  
2-I
[20]   Analytical performance of a high-pressure radio frequency-only quadrupole collision cell with an axial field applied by using conical rods [J].
Mansoori, BA ;
Dyer, EW ;
Lock, CM ;
Bateman, K ;
Boyd, RK ;
Thomson, BA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (08) :775-788