In vitro hydrodynamics of a decellularized pulmonary porcine valve, compared with a glutaraldehyde and polyurethane heart valve

被引:12
作者
Dohmen, PM [1 ]
Scheckel, M
Stein-Konertz, M
Erdbruegger, W
Affeld, K
Konertz, W
机构
[1] Humboldt Univ, Charite, Dept Cardiovasc Surg, Berlin, Germany
[2] Humboldt Univ, Biofluidmech Lab, Berlin, Germany
[3] Auto Tissue Ltd, Berlin, Germany
关键词
tissue-engineering; in vitro hemodynamics; versatile pulse duplicator;
D O I
10.1177/039139880202501108
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Hydrodynamic performance of a decellularized pulmonary porcine valve was evaluated with a computer versatile pulse duplicator and compared to glutaraldehyde fixated stentless porcine bioprosthesis and a polyurethane heart valve. Methods: Decellularized pulmonary porcine matrices (Group I, n=5) were treated chemically to become cell-free collagen matrices. The findings of this heart valve were compared with aortic glutaraldehyde treated porcine prostheses (Group II, n=5) and polyurethane three leaflet valve prostheses (Group II), n=1 Measurements were performed in 0.9% saline test fluid at room temperature. Measurements compared were closing time, closing volume, systemic pressure difference and energy losses. Each valve was measured 6 times with 70 beats/minute, a stroke volume of 70 ml corresponds to a cardiac output of 4.9 L/minute. Results: Group I and group III showed no significant differences between parameters. The measured closing time was significantly different (p<0.001) between group I and II, respectively 24.333 and 53.600 ms and group II and III respectively 53.600 and 24.000. Difference in closing volume was significant (p<0.05) between groups II and I respectively 3.67 and 0.68 ms and group II and III respectively 3.67 and 0.71. Systolic mean pressure gradient was 18.25 +/- 1.04 mm Hg in group II which was significantly different (p<0.001) from groups I and III, respectively 10.65 +/- 0.29 mm Hg and 7.70 +/- 0.30 mm Hg. Conclusions: Decellularized pulmonary porcine valves showed the same excellent performance as polyurethane valve prosthesis, which are superior to the investigated glutaraldehyde fixed xenograft.
引用
收藏
页码:1089 / 1094
页数:6
相关论文
共 22 条
[1]   PROSTHETIC HEART-VALVE EVALUATION INVITRO - CRITICAL ASPECTS OF DATA COMPARABILITY [J].
BARBARO, V ;
BARTOLINI, P ;
DANIELE, C ;
GRIGIONI, M ;
PALOMBO, A .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (06) :343-349
[2]  
Bernacca GM, 1997, J BIOMED MATER RES, V34, P371
[3]   Polyurethane heart valve durability: effects of leaflet thickness and material [J].
Bernacca, GM ;
Mackay, TG ;
Gulbransen, MJ ;
Donn, AW ;
Wheatley, DJ .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (06) :327-331
[4]   Steady flow in an aneurysm model: Correlation between fluid dynamics and blood platelet deposition [J].
Bluestein, D ;
Niu, L ;
Schoephoerster, RT ;
Dewanjee, MK .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03) :280-286
[5]  
Carr-White GS, 2001, CIRCULATION, V104, pI16
[6]   EFFECT OF 2-AMINO OLEIC-ACID EXPOSURE CONDITIONS ON THE INHIBITION OF CALCIFICATION OF GLUTARALDEHYDE CROSS-LINKED PORCINE AORTIC VALVES [J].
CHEN, WL ;
KIM, JD ;
SCHOEN, FJ ;
LEVY, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (12) :1485-1495
[7]  
HILBERT SL, 1987, J THORAC CARDIOV SUR, V94, P419
[8]  
KNOTT E, 1988, J THORAC CARDIOV SUR, V96, P952
[9]   CALCIFIC DEGENERATION AS THE MAIN CAUSE OF PORCINE BIOPROSTHETIC VALVE FAILURE [J].
MILANO, A ;
BORTOLOTTI, U ;
TALENTI, E ;
VALFRE, C ;
ARBUSTINI, E ;
VALENTE, M ;
MAZZUCCO, A ;
GALLUCCI, V ;
THIENE, G .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (08) :1066-1070
[10]  
NIMNI ME, 1968, J BIOL CHEM, V243, P1457