Monitoring the homogeneity of adenovirus preparations (a gene therapy delivery system) using analytical ultracentrifugation

被引:31
作者
Berkowitz, Steven A. [1 ]
Philo, John S.
机构
[1] Biogen Idec Inc, Dept Analyt Dev, Cambridge Ctr 14, Cambridge, MA 02142 USA
[2] Alliance Prot Labs, Thousand Oaks, CA 91360 USA
关键词
analytical ultracentrifugation; adenovirus; aggregation; empty capsids; gene therapy;
D O I
10.1016/j.ab.2006.11.031
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study explores the capability of modern analytical ultracentrifugation (AUC) to characterize the homogeneity, under product formulation conditions, of preparations of adenovirus vectors used in gene therapy and to assess the lot-to-lot consistency of this unique drug product. We demonstrate that a single sedimentation velocity run on an adenovirus sample can detect and accurately quantify a number of different forms of virus particles and subvirus particles. These forms include (a) intact virus monomer particles, (b) virus aggregates, (c) empty capsids (ECs), and (d) smaller assembly intermediates or subparticles formed during normal or aberrant virus assembly (or as a result of damage to the intact adenovirus or EC material during all phases of virus production). This information, which is collected on adenovirus samples under the exact formulation conditions that exist in the adenovirus vial, is obtained by direct boundary modeling of the AUC data generated from refractometric and/or UV detection systems using the computer program SEDFIT developed by Peter Schuck. Although both detectors are useful, refractometric detection using the Rayleigh interferometer offers a key advantage for providing accurate concentration information due to the similar response factors for both protein and DNA and its insensitivity to light scattering effects. Additional AUC data obtained from analytical band sedimentation velocity and density gradient sedimentation equilibrium experiments in CsCl with UV detection were also generated. These results further support conclusions concerning the solution properties of adenovirus, the identity of the different virus species, and the overall capability of boundary sedimentation velocity analysis. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:16 / 37
页数:22
相关论文
共 132 条
  • [41] THE ANALYTICAL ULTRACENTRIFUGE SPINS AGAIN
    HARDING, SE
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (10) : 439 - 446
  • [42] Hitt M M, 1997, Adv Pharmacol, V40, P137, DOI 10.1016/S1054-3589(08)60140-4
  • [43] HUGLIN MB, 1972, LIGHT SCATTERING POL, P165
  • [44] Hutchins B., 2002, Bioprocess. J, V1, P25, DOI [10.12665/J11.Hutchins, DOI 10.12665/J11, DOI 10.12665/J11.HUTCHINS]
  • [45] PURIFICATION OF A TYPE-5 RECOMBINANT ADENOVIRUS ENCODING HUMAN P53 BY COLUMN CHROMATOGRAPHY
    HUYGHE, BG
    LIU, XD
    SUTJIPTO, S
    SUGARMAN, BJ
    HORN, MT
    SHEPARD, HM
    SCANDELLA, CJ
    SHABRAM, P
    [J]. HUMAN GENE THERAPY, 1995, 6 (11) : 1403 - 1416
  • [46] Ifft J B, 1973, Methods Enzymol, V27, P128
  • [47] SEDIMENTATION EQUILIBRIUM OF PROTEINS IN DENSITY GRADIENTS
    IFFT, JB
    [J]. BIOPHYSICAL CHEMISTRY, 1976, 5 (1-2) : 137 - 157
  • [48] POLYPEPTIDES OF ADENOVIRUS .5. YOUNG VIRIONS, STRUCTURAL INTERMEDIATE BETWEEN TOP COMPONENTS AND AGED VIRIONS
    ISHIBASHI, M
    MAIZEL, JV
    [J]. VIROLOGY, 1974, 57 (02) : 409 - 424
  • [49] Improved high-performance liquid chromatographic method in the analysis of adenovirus particles
    Klyushnichenko, V
    Bernier, A
    Kamen, A
    Harmsen, E
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 755 (1-2): : 27 - 36
  • [50] KOHLER K, 1962, Z NATURFORSCH PT B, VB 17, P544