High-precision isotopic analysis of palmitoylcarnitine by liquid chromatography/electrospray ionization ion-trap tandem mass spectrometry

被引:6
作者
Guo, ZengKui
Yarasheski, Kevin
Jensen, Michael D.
机构
[1] Mayo Fdn, Endocrine Res Unit, Rochester, MN 55905 USA
[2] Washington Univ, Dept Med, St Louis, MO 63130 USA
关键词
D O I
10.1002/rcm.2753
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Single quadrupole gas chromatography/mass spectrometry (GC/MS) has been widely used for isotopic analysis in metabolic investigations using stable isotopes as tracers. However, its inherent shortcomings prohibit it from broader use, including low isotopic precision and the need for chemical derivatization of the analyte. In order to improve isotopic detection power, liquid chromatography/electrospray ionization ion-trap tandem mass spectrometry (LC/ESI-itMS2) has been evaluated for its isotopic precision and chemical sensitivity for the analysis of [C-13]palmitoylcarnitine. Over the enrichment range of 0.4-10 MPE (molar % excess), the isotopic response of LC/ESI-itMS2 to [C-13]palmitoylcarnitine was linear (r=1.00) and the average isotopic precision (standard deviation, SD) was 0.11 MPE with an average coefficient of variation (CV) of 5.6%. At the lower end of isotopic enrichments (0.4-0.9 MPE), the isotopic precision was 0.05 MPE (CV=8%). Routine analysis of rat skeletal muscle [C-13(4)]palmitoylcarnitine demonstrated an isotopic precision of 0.03 MPE for gastrocnemius (n=16) and of 0.02 MPE for tibialis anterior (n=16). The high precision enabled the detection of a small (0.08 MPE) but significant (P=0.01) difference in [C-13(4)]palmitoylcarnitine enrichments between the two muscles, 0.51 MPE (CV=5.8%) and 0.43 MPE (CV=4.6%), respectively. Therefore, the system demonstrated an isotopic lower detection limit (LDL) of <= 0.1 MPE (2 X SD) that has been impossible previously with other organic mass spectrometry instruments. LC/ESI-itMS2 systems have the potential to advance metabolic investigations using stable isotopes to a new level by significantly increasing the isotopic solving power. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:3361 / 3366
页数:6
相关论文
共 9 条
[1]  
Che FY, 1999, ELECTROPHORESIS, V20, P2930, DOI 10.1002/(SICI)1522-2683(19991001)20:14<2930::AID-ELPS2930>3.3.CO
[2]  
2-O
[3]   Structure characterization of flavonoid O-diglycosides by positive and negative nano-electrospray ionization ion trap mass spectrometry [J].
Cuyckens, F ;
Rozenberg, R ;
de Hoffmann, E ;
Claeys, M .
JOURNAL OF MASS SPECTROMETRY, 2001, 36 (11) :1203-1210
[4]   Intramuscular fatty acid metabolism evaluated with stable isotopic tracers [J].
Guo, ZK ;
Jensen, MD .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (05) :1674-1679
[5]   COMPOUND-SPECIFIC CARBON-ISOTOPE RATIO DETERMINATION OF ENRICHED CHOLESTEROL [J].
GUO, ZK ;
LUKE, AH ;
LEE, WP ;
SCHOELLER, D .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :1954-1959
[6]   Structure elucidation of nanogram quantities of unknown designer drugs based on phenylalkylamine derivates by ion trap multiple mass spectrometry [J].
Kölliker, S ;
Oehme, M .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (05) :1294-1304
[7]   SIMPLE AND UNAMBIGUOUS METHOD FOR IDENTIFYING URINARY ACYLCARNITINES USING GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
LOWES, S ;
ROSE, ME .
ANALYST, 1990, 115 (05) :511-516
[8]   Measurement of homocysteine concentrations and stable isotope tracer enrichments in human plasma [J].
MacCoss, MJ ;
Fukagawa, NK ;
Matthews, DE .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4527-4533
[9]   Measurement of stable isotopic enrichment and concentration of long-chain fatty acyl-carnitines in tissue by HPLC-MS [J].
Sun, DY ;
Cree, MG ;
Zhang, XJ ;
Boersheim, E ;
Wolfe, RR .
JOURNAL OF LIPID RESEARCH, 2006, 47 (02) :431-439