Personalized ventilation: evaluation of different air terminal devices

被引:356
作者
Melikov, AK [1 ]
Cermak, R [1 ]
Majer, M [1 ]
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
personalized ventilation; air distribution; air quality; thermal comfort;
D O I
10.1016/S0378-7788(02)00102-0
中图分类号
TU [建筑科学];
学科分类号
0813 [建筑学];
摘要
Personalized ventilation (PV) aims to provide clean air to the breathing zone of occupants. Its performance depends to a large extent on the supply air terminal device (ATD). Five different ATDs were developed, tested and compared. A typical office workplace consisting of a desk with mounted ATDs was simulated in a climate chamber. A breathing thermal manikin was used to simulate a human being. Experiments at room air temperatures of 26 and 20 degreesC and personalized air temperatures of 20 degreesC supplied from the ATDs were performed. The flow rate of personalized air was changed from less than 5 up to 23 l/s. Tracer gas was used to identify the amount of personalized air inhaled by the manikin as well as the amount of exhaled air re-inhaled. The heat loss from the body segments of the thermal manikin was. measured and used to calculate the equivalent temperature for the whole body as well as segments of the body. An index, personal exposure effectiveness, was used to assess the performance of ATDs in regard to quality of the air inhaled by the manikin. The personal exposure effectiveness increased with the increase of the airflow rate from the ATD to a constant maximum value. A further increase of the airflow rate had no impact on the personal exposure effectiveness. Under both isothermal and non-isothermal conditions the highest personal exposure effectiveness of 0.6 was achieved by a vertical desk grill followed by an ATD designed as a movable panel. The ATDs tested performed differently in regard to the inhaled air temperature used as another air quality indicator, as well as in regard to the equivalent temperature. The results suggest that PV may decrease significantly the number of occupants dissatisfied with the air quality. However, an ATD that will ensure more efficient distribution and less mixing of the personalized air with the polluted room air needs to be developed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:829 / 836
页数:8
相关论文
共 21 条
[1]
*ASHRAE, 1989, 621989 ASHRAE INC
[2]
Personal exposure in displacement ventilated rooms [J].
Brohus, H ;
Nielsen, PV .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (03) :157-167
[3]
BROHUS H, 1997, P VENT 97 GLOB DEV I, V2, P781
[4]
*EUR COMM STAND, 1998, 1752 CEN CR EUR COMM
[5]
Impact of temperature and humidity on chemical and sensory emissions from building materials [J].
Fang, L ;
Clausen, G ;
Fanger, PO .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (03) :193-201
[6]
Impact of temperature and humidity on the perception of indoor air quality [J].
Fang, L ;
Clausen, G ;
Fanger, PO .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (02) :80-90
[7]
AIR TURBULENCE AND SENSATION OF DRAFT [J].
FANGER, PO ;
MELIKOV, AK ;
HANZAWA, H ;
RING, J .
ENERGY AND BUILDINGS, 1988, 12 (01) :21-39
[8]
Ventilation efficiencies of desk-mounted task/ambient conditioning systems [J].
Faulkner, D ;
Fisk, WJ ;
Sullivan, DP ;
Wyon, DP .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1999, 9 (04) :273-281
[9]
ISO, 1994, 7730 ISO
[10]
KJERULFJENSEN P, 1975, ASHRAE J, V17, P65