Digital mammography using storage phosphor plate technique - Optimizing image processing parameters for the visibility of lesions and anatomy

被引:8
作者
Kheddache, S
Kvist, H
机构
[1] Goteborg University, Department of Radiology, Sahlgrenska Hospital
关键词
diagnostic radiology; radiography digital; mammography radiography; image processing;
D O I
10.1016/S0720-048X(97)01040-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital mammograms from a storage phosphor plate system for general radiography were compared to conventional mammograms by means of visual grading analysis (VGA). For the digital images, image processing parameters were optimized and evaluated through observer preference analysis (OPA). The results of the VGA showed significantly better gradings for the conventional mammograms for parenchyma, linear structures, and cysts, and significantly better gradings for the digital mammograms for the skin surface. For calcifications, no significant difference was seen. For the OPA, contrast enhanced mammograms graded significantly best. Using standard image processing, the digital mammograms were considered as adequate for diagnosis in 49% of the cases, as uncertain in 20%, and as inadequate in 31%. However, the observers differed considerably in their gradings both in the VGA and in the OPA. (C) 1997 Elsevier Science Ireland Ltd.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 13 条
  • [1] EVALUATION OF MAMMOGRAPHIC IMAGE QUALITY - PILOT-STUDY COMPARING 5 METHODS
    CALDWELL, CB
    FISHELL, EK
    JONG, RA
    WEISER, WJ
    YAFFE, MJ
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (02) : 295 - 301
  • [2] DIGITAL MAMMOGRAPHY - ROC STUDIES OF THE EFFECTS OF PIXEL SIZE AND UNSHARP-MASK FILTERING ON THE DETECTION OF SUBTLE MICROCALCIFICATIONS
    CHAN, HP
    VYBORNY, CJ
    MACMAHON, H
    METZ, CE
    DOI, K
    SICKLES, EA
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (07) : 581 - 589
  • [3] DETECTION OF SUBTLE MICROCALCIFICATIONS - COMPARISON OF COMPUTED RADIOGRAPHY AND SCREEN-FILM MAMMOGRAPHY
    HIGASHIDA, Y
    MORIBE, N
    MORITA, K
    KATSUDA, N
    HATEMURA, M
    TAKADA, T
    TAKAHASHI, M
    YAMASHITA, J
    [J]. RADIOLOGY, 1992, 183 (02) : 483 - 486
  • [4] JARLMAN O, 1991, ACTA RADIOL, V32, P110
  • [5] JARLMAN O, 1994, CANCER DETECT PREV, V18, P375
  • [6] KHEDDACHE S, 1993, ACTA RADIOL, V34, P618
  • [7] LARGE-SCREEN IMAGE INTENSIFIER PHOTOFLUOROGRAPHY COMPARED WITH FULL-SIZE SCREEN-FILM TECHNIQUE IN CHEST RADIOGRAPHY
    MANNINEN, H
    RYTKONEN, H
    SOIMAKALLIO, S
    TERHO, EO
    HENTUNEN, J
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1985, 26 (05): : 525 - 533
  • [8] BASIC PRINCIPLES OF ROC ANALYSIS
    METZ, CE
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1978, 8 (04) : 283 - 298
  • [9] COMPARISON OF DIGITAL AND CONVENTIONAL MAMMOGRAPHY - A ROC STUDY OF 270 MAMMOGRAMS
    NAB, HW
    KARSSEMEIJER, N
    VANERNING, LJTHO
    HENDRIKS, JHCL
    [J]. MEDICAL INFORMATICS, 1992, 17 (02): : 125 - 131
  • [10] A COMPARISON OF DIGITIZED STORAGE PHOSPHORS AND CONVENTIONAL MAMMOGRAPHY IN THE DETECTION OF MALIGNANT MICROCALCIFICATIONS
    OESTMANN, JW
    KOPANS, D
    HALL, DA
    MCCARTHY, KA
    RUBENS, JR
    GREENE, R
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (10) : 725 - 728