Broad bandwidth frequency domain instrument for quantitative tissue optical spectroscopy

被引:215
作者
Pham, TH
Coquoz, O
Fishkin, JB
Anderson, E
Tromberg, BJ
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Laser Microbeam & Med Program, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Dept Elect & Comp Engn, Irvine, CA 92612 USA
[3] Ecole Polytech Fed Lausanne, IOA, CH-1015 Lausanne, Switzerland
[4] EA Photon, Redondo Beach, CA 90278 USA
关键词
D O I
10.1063/1.1150665
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Near-infrared (NIR) optical properties of turbid media, e.g., tissue, can be accurately quantified noninvasively using methods based on diffuse reflectance or transmittance, such as frequency domain photon migration (FDPM). Factors which govern the accuracy and sensitivity of FDPM-measured optical properties include instrument performance, the light propagation model, and fitting algorithms used to calculate optical properties from measured data. In this article, we characterize instrument, model, and fitting uncertaintics of an FDPM system designed for clinical use and investigate how each of these factors affects the quantification of NIR absorption (mu(a)) and reduced scattering (mu(s)') parameters in tissue phantoms. The instrument is based on a 500 MHz, multiwavelength platform that sweeps through 201 discrete frequencies in as little as 675 ms. Phase and amplitude of intensity modulated light launched into tissue, i.e., diffuse photon density waves (PDW), are measured with an accuracy of +/- 0.30 degrees and +/- 3.5%, while phase and amplitude precision are +/- 0.025 degrees and +/- 0.20%, respectively. At this level of instrument uncertainty, simultaneous fitting of frequency-dependent phase and amplitude nonlinear model functions derived from a photon diffusion approximation provides an accurate and robust strategy for determining optical properties from FDPM data, especially for media with high absorption. In an optical property range that is characteristic of most human tissues in the NIR (5 x 10(-3) < mu(a) < 5 x 10(-2) mm(-1), 0.5 < mu(s)' < 2 mm(-1)), we theoretically and experimentally demonstrate that the multifrequency, simultaneous-fit approach allows mu(a) and mu(s)' to be quantified with an accuracy of +/- 5% and +/- 3%, respectively. Although exceptionally high levels of precision can be obtained using this approach (< 1% of the estimated absorption and scattering values), we show that the absolute accuracy of optical property measurements is highly dependent on specific factors associated with instrument performance, model function relevance, and details of the fitting strategy used to calculate mu(a) and mu(s)'. (C) 2000 American Institute of Physics. [S0034-6748(00)00106-4].
引用
收藏
页码:2500 / 2513
页数:14
相关论文
共 39 条
[21]   TIME-RESOLVED REFLECTANCE SPECTROSCOPY IN TURBID TISSUES [J].
JACQUES, SL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (12) :1155-1161
[22]   In vivo measurements of the wavelength dependence of tissue-scattering coefficients between 760 and 900 nm measured with time-resolved spectroscopy [J].
Matcher, SJ ;
Cope, M ;
Delpy, DT .
APPLIED OPTICS, 1997, 36 (01) :386-396
[23]  
MOHANDAS N, 1986, BLOOD, V68, P506
[24]   Mechanisms of light scattering from biological cells relevant to noninvasive optical-tissue diagnostics [J].
Mourant, JR ;
Freyer, JP ;
Hielscher, AH ;
Eick, AA ;
Shen, D ;
Johnson, TM .
APPLIED OPTICS, 1998, 37 (16) :3586-3593
[25]  
Patterson M. S., 1991, IEEE MICROWAVE THEOR, VBB-1, P905, DOI DOI 10.1109/MWSYM.1991.147155
[26]   FREQUENCY-DOMAIN REFLECTANCE FOR THE DETERMINATION OF THE SCATTERING AND ABSORPTION PROPERTIES OF TISSUE [J].
PATTERSON, MS ;
MOULTON, JD ;
WILSON, BC ;
BERNDT, KW ;
LAKOWICZ, JR .
APPLIED OPTICS, 1991, 30 (31) :4474-4476
[27]   TIME RESOLVED REFLECTANCE AND TRANSMITTANCE FOR THE NONINVASIVE MEASUREMENT OF TISSUE OPTICAL-PROPERTIES [J].
PATTERSON, MS ;
CHANCE, B ;
WILSON, BC .
APPLIED OPTICS, 1989, 28 (12) :2331-2336
[28]  
Press WH, 1992, NUMERICAL RECIPES C, V2
[29]   MIE AND RAYLEIGH MODELING OF VISIBLE-LIGHT SCATTERING IN NEONATAL SKIN [J].
SAIDI, IS ;
JACQUES, SL ;
TITTEL, FK .
APPLIED OPTICS, 1995, 34 (31) :7410-7418
[30]   Polarization discrimination of coherently propagating light in turbid media [J].
Sankaran, V ;
Schönenberger, K ;
Walsh, JT ;
Maitland, DJ .
APPLIED OPTICS, 1999, 38 (19) :4252-4261