Solid-contact potentiometric polymer membrane microelectrodes for the detection of silver ions at the femtomole level

被引:73
作者
Rubinova, Nastassia [1 ]
Chumbimuni-Torres, Karin [1 ]
Bakker, Eric [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
potentiometry; poly(octylthiophene); solid inner contact; low detection limit; miniaturization;
D O I
10.1016/j.snb.2006.09.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years, ion-selective electrodes based on polymer membranes have been shown to exhibit detection limits that are often in the nanomolar concentration range, and thus drastically lower than traditionally accepted. Since potentiometry is less dependent on scaling laws that other established analytical techniques, their performance in confined sample volumes is explored here. Solid-contact silver-selective microelectrodes, with a sodium-selective microelectrode as a reference, were inserted into a micropipette tip used as a 50-mu l sample. The observed potential stabilities, reproducibilities and detection limits were attractive and largely matched that for large 100-ml samples. This should pave the way for further experiments to detecting ultra-small total ion concentrations by potentiometry, especially when used as a transducer after an amplification step in bioanalysis. (c) 2006 Published by Elsevier B.V.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 42 条
[1]  
Ammann, 1986, ION SELECTIVE MICROE
[2]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[3]   SOME ALKYLPHOSPHORIC ACID-ESTERS FOR USE IN COATED-WIRE CALCIUM-SELECTIVE ELECTRODES .1. RESPONSE CHARACTERISTICS [J].
CATTRALL, RW ;
DREW, DM ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1975, 76 (02) :269-277
[4]   Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS [J].
Ceresa, A ;
Bakker, E ;
Hattendorf, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :343-351
[5]   In situ assembled mass-transport controlling micromembranes and their application in implanted amperometric glucose sensors [J].
Chen, T ;
Friedman, KA ;
Lei, I ;
Heller, A .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3757-3763
[6]   Solid contact potentiometric sensors for trace level measurements [J].
Chumbimuni-Torres, KY ;
Rubinova, N ;
Radu, A ;
Kubota, LT ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2006, 78 (04) :1318-1322
[7]  
Fibbioli M, 2000, ELECTROANAL, V12, P1286, DOI 10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.3.CO
[8]  
2-H
[9]  
Grekovich AL, 2002, ELECTROANAL, V14, P551, DOI 10.1002/1521-4109(200204)14:7/8<551::AID-ELAN551>3.0.CO
[10]  
2-W