A comparison of within- and between-day reliability of discrete 3D lower extremity variables in runners

被引:137
作者
Ferber, R [1 ]
Davis, IM
Williams, DS
Laughton, C
机构
[1] Univ Delaware, Dept Phys Therapy, Motin Anal Lab, McKinly Lab 301, Newark, DE 19717 USA
[2] Joyner Sportsmed Inst, Harrisburg, PA 17111 USA
[3] E Carolina Univ, Dept Phys Therapy, Greenville, NC 27858 USA
[4] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
关键词
gait analysis; repeatability; kinematics; kinetics;
D O I
10.1016/S0736-0266(02)00077-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
It is important to understand the day-to-day variability that is attributed to repositioning of markers especially when assessing a treatment effect or response over time. While previous studies have reported reliability of waveform patterns, none have assessed the repeatability of discrete points such as peak angles, velocities and angular excursions which are often used when making statistical and clinical comparisons. The purpose of this study was to compare the within- and between-day variability of discrete kinematic, kinetic, and ground reaction force (GRF) data collected during running. Comparisons for 20 recreational runners were evaluated for within- and between-day reliability of discrete 3D kinematic, kinetic, and GRF variables. The results indicated that within-day comparisons were more reliable than between-day. Joint angular velocity and angular excursion values were more reliable between-days as compared to absolute peak angle measures and may be more useful in interpreting changes in treatment over time. Between-day kinematic and kinetic sagittal plane values were more reliable than secondary plane values. Reliability of GRF data was greater than kinematic and kinetic data for between-day comparisons. (C) 2002 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1139 / 1145
页数:7
相关论文
共 9 条
[1]
Kinematic analysis of a multi-segment foot model for research and clinical applications: a repeatability analysis [J].
Carson, MC ;
Harrington, ME ;
Thompson, N ;
O'Connor, JJ ;
Theologis, TN .
JOURNAL OF BIOMECHANICS, 2001, 34 (10) :1299-1307
[2]
Dempster W, 1959, WADC TECHNICAL REPOR, P55
[3]
REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860
[4]
Kyröläinen H, 2001, MED SCI SPORT EXER, V33, P1330
[5]
Three-dimensional, six-degrees-of-freedom kinematics of the human hindfoot during the stance phase of level walking [J].
Liu, W ;
Siegler, S ;
Hillstrom, H ;
Whitney, K .
HUMAN MOVEMENT SCIENCE, 1997, 16 (2-3) :283-298
[6]
Comparison of surface mounted markers and attachment methods in estimating tibial rotations during walking: an in vivo study [J].
Manal, K ;
McClay, I ;
Stanhope, S ;
Richards, J ;
Galinat, B .
GAIT & POSTURE, 2000, 11 (01) :38-45
[7]
Effect of skin movement on the analysis of skeletal knee joint motion during running [J].
Reinschmidt, C ;
vandenBogert, AJ ;
Nigg, BM ;
Lundberg, A ;
Murphy, N .
JOURNAL OF BIOMECHANICS, 1997, 30 (07) :729-732
[8]
Intrasubject repeatability of gait analysis data in normal and spastic children [J].
Steinwender, G ;
Saraph, V ;
Scheiber, S ;
Zwick, EB ;
Uitz, C ;
Hackl, K .
CLINICAL BIOMECHANICS, 2000, 15 (02) :134-139