Immobilized 1,5-diphenylcarbazone as a complexing agent for on-line trace enrichment and determination of copper by flow injection-atomic absorption spectroscopy

被引:31
作者
Dadfarnia, S [1 ]
Salmanzadeh, AM [1 ]
Shabani, AMH [1 ]
机构
[1] Yazd Univ, Dept Chem, Yazd, Iran
关键词
D O I
10.1039/b204966j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid on- line preconcentration technique for the determination of copper in different samples by FI- AAS has been devised. Preconcentration is based on the deposition of analyte on a micro- column of 1,5- diphenylcarbazone immobilized on surfactant coated alumina and subsequent elution by injection of a small volume of hydrobromic acid (500 mul of 0.75 mol l(-1) acid). A sample volume of 30 ml resulted in a preconcentration factor of 100, and precisions at the 100 and 10 mug l(-1) levels were 3.2 and 3.5% RSD, respectively. The procedure was applied to spring water, well water, sea- water, stainless steel and a multivitamin tablet and the accuracy was assessed through recovery experiments, independent analysis by furnace- AAS, and the analysis of a certified reference material.
引用
收藏
页码:1434 / 1438
页数:5
相关论文
共 25 条
[1]   1,10-phenanthroline as a complexing agent for on-line sorbent extraction preconcentration for flow injection-flame atomic absorption spectrometry [J].
Ali, A ;
Yin, XF ;
Shen, H ;
Ye, YX ;
Gu, X .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :283-289
[2]  
ALLOWAY BJ, 1993, CHEM PRINCIPLES ENV, P161
[3]   On-line solid phase extraction system using PTFE packed column for the flame atomic absorption spectrometric determination of copper in water samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
TALANTA, 2001, 54 (05) :935-942
[4]   Simultaneous determination of Cd(II), Cu(II) and Pb(II) in surface waters by solid phase extraction and flow injection analysis with spectrophotometric detection [J].
Castillo, E ;
Cortina, JL ;
Beltrán, JL ;
Prat, MD ;
Granados, M .
ANALYST, 2001, 126 (07) :1149-1153
[5]   ONLINE TRACE ENRICHMENT AND DETERMINATION OF URANIUM IN WATERS BY FLOW-INJECTION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
DADFARNIA, S ;
MCLEOD, CW .
APPLIED SPECTROSCOPY, 1994, 48 (11) :1331-1336
[6]  
Dadfarnia Shayessteh, 1994, Analytical Proceedings, V31, P61, DOI 10.1039/ai9943100061
[7]   An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy [J].
Ferreira, SLC ;
Lemos, VA ;
Moreira, BC ;
Costa, ACS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :259-264
[8]  
FUKKAMACHI K, 1981, ANAL CHIM ACTA, V119, P383
[9]   IMMOBILIZATION OF DITHIZONE ON SURFACTANT-COATED ALUMINA FOR PRECONCENTRATION OF METAL-IONS [J].
HIRAIDE, M ;
SOROURADIN, MH ;
KAWAGUCHI, H .
ANALYTICAL SCIENCES, 1994, 10 (01) :125-127
[10]   IMMOBILIZATION OF 1-NITROSO-2-NAPHTHOL ON SURFACTANT-COATED ALUMINA FOR THE COLLECTION OF TRACES OF COBALT(II) IONS [J].
HIRAIDE, M ;
OHTA, Y ;
KAWAGUCHI, H .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (10-11) :648-650