In vivo lipid diffusion coefficient measurements in rat bone marrow

被引:25
作者
Ababneh, Zaid Q. [1 ]
Beloeil, Helene [2 ]
Berde, Charles B. [2 ]
Ababneh, Anas M. [1 ]
Maier, Stephan E. [3 ]
Mulkern, Robert V. [3 ,4 ]
机构
[1] Yarmouk Univ, Dept Phys, Irbid 21163, Jordan
[2] Harvard Univ, Childrens Hosp, Sch Med, Dept Anesthesia, Boston, MA 02115 USA
[3] Harvard Univ, Childrens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
[4] Harvard Univ, Brigham & Womens Hosp, Sch Med, Dept Radiol, Boston, MA 02115 USA
关键词
Bone marrow; Diffusion; Relaxation; Lipid; FATTY-ACID COMPOSITION; ADIPOSE-TISSUE; FIELD GRADIENT; SYSTEM; DECAY; MRI;
D O I
10.1016/j.mri.2008.11.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
The diffusion coefficient of lipids, D(l), within bone marrow, fat deposits and metabolically active intracellular lipids in vivo will depend on several factors including the precise chemical composition of the lipid distribution (chain lengths, degree of unsaturation, etc.) as well as the temperature. As such, D(l) may ultimately prove of value in assessing abnormal fatty acid distributions linked to diseases such as cystic fibrosis, diabetes and coronary heart disease. A sensitive temperature dependence of D(l) may also prove of value for MR-guided thermal therapies for bone tumors or disease within other fatty tissues like the breast. Measuring diffusion coefficients of high molecular weight lipids in vivo is, however, technically difficult for a number of reasons. For instance, due to the much lower diffusion coefficients compared to water, much higher b factors than those used for central nervous system applications are needed. In addition, the pulse sequence design must incorporate, as much as possible, immunity to motion, susceptibility and chemical shift effects present whenever body imaging is performed. In this work, high b-factor line scan diffusion imaging sequences were designed, implemented and tested for D(l) measurement using a 4.7-T horizontal bore animal scanner. The gradient set available allowed for b factors as high as 0.03 mu s/nm(2) (30,000 s/mm(2)) at echo times as short as 42 ms. The methods were used to measure lipid diffusion coefficients within the marrow of rat paws in vivo, yielding lipid diffusion coefficients approximately two orders of magnitude smaller than typical tissue water diffusion coefficients. Phantom experiments that demonstrate the sensitivity of lipid diffusion coefficients to chain length and temperature were also performed. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:859 / 864
页数:6
相关论文
共 22 条
[1]
Biexponential parameterization of diffusion and T2 relaxation decay curves in a rat muscle edema model:: Decay curve components and water compartments [J].
Ababneh, Z ;
Beloeil, H ;
Berde, CB ;
Gambarota, G ;
Maier, SE ;
Mulkern, RV .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) :524-531
[2]
Dairy cream as a phantom material for biexponential diffusion decay [J].
Ababneh, Z ;
Haque, M ;
Maier, SE ;
Mulkern, RV .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2004, 17 (02) :95-100
[4]
MATHEMATICAL RELATIONSHIP BETWEEN THE FATTY-ACID COMPOSITION OF THE DIET AND THAT OF THE ADIPOSE-TISSUE IN MAN [J].
BEYNEN, AC ;
HERMUS, RJJ ;
HAUTVAST, JGAJ .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1980, 33 (01) :81-85
[5]
Free fatty acids, insulin resistance, and type 2 diabetes mellitus [J].
Boden, G .
PROCEEDINGS OF THE ASSOCIATION OF AMERICAN PHYSICIANS, 1999, 111 (03) :241-248
[6]
CAMPBELL IM, 1976, PEDIATRICS, V57, P480
[7]
Line scan diffusion imaging [J].
Gudbjartsson, H ;
Maier, SE ;
Mulkern, RV ;
Morocz, IA ;
Patz, S ;
Jolesz, FA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) :509-519
[8]
In situ pulsed-field gradient NMR determination of the size of oil bodies in vegetable seeds. Analysis of the effect of the gradient pulse length [J].
Guillermo, Armel ;
Bardet, Michel .
ANALYTICAL CHEMISTRY, 2007, 79 (17) :6718-6726
[9]
Hynynen K, 2000, MAGNET RESON MED, V43, P901, DOI 10.1002/1522-2594(200006)43:6<901::AID-MRM18>3.0.CO
[10]
2-A