Development and validation of a liquid chromatographic-tandem mass spectrometric method for the determination of pibutidine in human urine

被引:4
作者
Kato, K [1 ]
Jingu, S [1 ]
Ogawa, N [1 ]
Higuchi, S [1 ]
机构
[1] Taisho Pharmaceut Co Ltd, Pharmaceut Res Labs, Drug Metab Lab, Omiya, Saitama 3308530, Japan
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 740卷 / 02期
关键词
pibutidine;
D O I
10.1016/S0378-4347(00)00099-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatographic-tandem mass spectrometric method for the rapid quantitative determination of pibutidine, an H-2-receptor antagonist, in human urine has been developed and validated over the concentration range 0.1-25.6 mu g ml(-1). Urine samples were prepared based on a simple dilution with 0.05% acetic acid, followed by reversed-phase Liquid chromatographic separation. Pibutidine and its internal standard (H-2(10)-pibutidine) were ionized using an electrospray ionization interface and detected by tandem mass spectrometry in the selected reaction-monitoring mode. Completed validation demonstrated the method to be robust, accurate, precise and specific for the direct quantification of pibutidine in human urine. This method has enabled investigation of the urinary excretion of pibutidine following oral administration of pibutidine hydrochloride to healthy subjects. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 14 条
[1]  
AZUMA J, 1999, JPN PHARMACOL THER, V27, pS973
[2]   Determination of SR 49059 in human plasma and urine by LC-APCI/MS/MS [J].
Burton, R ;
Mummert, M ;
Newton, J ;
Brouard, R ;
Wu, DL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (12) :1913-1922
[3]   Use of liquid chromatography tandem mass spectrometry for the quantitative and qualitative analysis of an antipsychotic agent and its metabolites in human plasma and urine [J].
Dear, GJ ;
Fraser, IJ ;
Patel, DK ;
Long, J ;
Pleasance, S .
JOURNAL OF CHROMATOGRAPHY A, 1998, 794 (1-2) :27-36
[4]   Effect of the sample matrix on the determination of indinavir in human urine by HPLC with turbo ion spray tandem mass spectrometric detection [J].
Fu, I ;
Woolf, EJ ;
Matuszewski, BK .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (03) :347-357
[5]  
ISOBE Y, 1999, JPN PHARMACOL THER, V27, P261
[6]  
Kato K, 1999, RAPID COMMUN MASS SP, V13, P1626
[7]  
Kebarle P. A., 1993, ANAL CHEM, V65, P972
[8]   PHARMACOKINETIC AND PHARMACODYNAMIC PROPERTIES OF HISTAMINE H-2-RECEPTOR ANTAGONISTS - RELATIONSHIP BETWEEN INTRINSIC POTENCY AND EFFECTIVE PLASMA-CONCENTRATIONS [J].
LIN, JH .
CLINICAL PHARMACOKINETICS, 1991, 20 (03) :218-236
[9]   Development of high-performance liquid chromatography tandem mass spectrometric methods for the determination of a new oxytocin receptor antagonist (L-368,899) extracted from human plasma and urine: a case of lack of specificity due to the presence of metabolites [J].
Matuszewski, BK ;
Chavez-Eng, CM ;
Constanzer, ML .
JOURNAL OF CHROMATOGRAPHY B, 1998, 716 (1-2) :195-208
[10]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889