Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads

被引:367
作者
Centi, Sonia [1 ]
Tombelli, Sara [1 ]
Minunni, Maria [1 ]
Mascini, Marco [1 ]
机构
[1] Univ Florence, I-50019 Sesto Fiorentino, Italy
关键词
D O I
10.1021/ac061879p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The DNA thrombin aptamer has been extensively investigated, and the coupling of this aptamer to different transduction principles has demonstrated the wide applicability of aptamers as bioreceptors in bioanalytical assays. The goal of this work was to design an aptamer-based sandwich assay with electrochemical detection for thrombin analysis in complex matrixes, using a simple target capturing step by aptamer-functionalized magnetic beads. The conditions for the aptamer immobilization and for the protein binding have been first optimized by surface plasmon resonance, and then transferred to the electrochemical-based assay performed onto screen-printed electrodes. The assay was then applied to the analysis of thrombin in buffer, spiked serum, and plasma and high sensitivity and specificity were found. Moreover, thrombin was generated in situ in plasma by the conversion of its precursor prothrombin, and the formation of thrombin was followed at different times. The concentrations detected by the electrochemical assay were in agreement with a simulation software that mimics the formation of thrombin over time (thrombogram). The proposed work demonstrates that the high specificity of aptamers together with the use of magnetic beads are the key features for aptamer-based analysis in complex matrixes, opening the possibility of a real application to diagnostics or medical investigation.
引用
收藏
页码:1466 / 1473
页数:8
相关论文
共 40 条
[1]   Aptasensor development: Elucidation of critical parameters for optimal aptamer performance [J].
Baldrich, E ;
Restrepo, A ;
O'Sullivan, CK .
ANALYTICAL CHEMISTRY, 2004, 76 (23) :7053-7063
[2]   A novel electrochemical detection method for aptamer biosensors [J].
Bang, GS ;
Cho, S ;
Kim, BG .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) :863-870
[3]   Detection of thrombin in human blood by ex-vivo hirudin [J].
Bichler, J ;
Heit, JA ;
Owen, WG .
THROMBOSIS RESEARCH, 1996, 84 (04) :289-294
[4]   SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN [J].
BOCK, LC ;
GRIFFIN, LC ;
LATHAM, JA ;
VERMAAS, EH ;
TOOLE, JJ .
NATURE, 1992, 355 (6360) :564-566
[5]   Label-free protein recognition using an aptamer-based impedance measurement assay [J].
Cai, H ;
Lee, TMH ;
Hsing, IM .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :433-437
[6]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[7]   Monitoring complex formation in the blood-coagulation cascade using aptamer-coated SAW sensors [J].
Gronewold, TMA ;
Glass, S ;
Quandt, E ;
Famulok, M .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :2044-2052
[8]   Aptamer beacons for the direct detection of proteins [J].
Hamaguchi, N ;
Ellington, A ;
Stanton, M .
ANALYTICAL BIOCHEMISTRY, 2001, 294 (02) :126-131
[9]   Calibrated automated thrombin generation measurement in clotting plasma [J].
Hemker, HC ;
Giesen, P ;
Al Dieri, R ;
Regnault, V ;
de Smedt, E ;
Wagenvoord, R ;
Lecompte, T ;
Béguin, S .
PATHOPHYSIOLOGY OF HAEMOSTASIS AND THROMBOSIS, 2003, 33 (01) :4-15
[10]   Nucleic acid-based fluorescence sensors for detecting proteins [J].
Heyduk, E ;
Heyduk, T .
ANALYTICAL CHEMISTRY, 2005, 77 (04) :1147-1156