Underevaluation of HIV-1 plasma viral load by a commercially available assay in a cluster of patients infected with HIV-1 A/G circulating recombinant form (CRF02)

被引:29
作者
Amendola, A
Bordi, L
Angeletti, C
Visco-Comandini, U
Abbate, I
Cappiello, G
Budabbus, MA
Eljhawi, OA
Mehabresh, MI
Girardi, E
Antinori, A
Ippolito, G
Capobianchi, MR
机构
[1] Lazzaro Spallanzani IRCCS, Natl Inst Infect Dis, Rome, Italy
[2] Sandro Pertini Hosp, Rome, Italy
[3] Embassy Popular Jamajria Libya, Rome, Italy
关键词
HIV-1; subtypes; Circulating recombinant form (CRF); A/G recombinant HIV-1; Viral load; Roche Amplicor Monitor; Bayer Versant; Organon Teknika NucliSens;
D O I
10.1097/00126334-200212150-00006
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The authors studied the correlation and agreement of commercially available assays in detection and quantification of the HIV-1 intersubtype A/G circulating recombinant form CRF02. The assays under comparison were Bayer Versant HIV-1 RNA, version 3.0; Roche Amplicor HIV-1 Monitor, version 1.5 (standard procedure); and Organon Teknika NucliSens HIV-1 RNA QT. Plasma samples from 114 patients infected with CRF02 were tested by the three assays under standard conditions. Although correlation among the assays was high and statistically significant for subtype B and CRF02, in the latter instance, NucliSens measured average viral load values (3.29 +/- 0.71 log(10) copies/mL) about 4 and >8 times lower than those obtained by Versant (3.90 +/- 0.90 log(10) copies/mL) and Amplicor (4.22 +/- 1.05 log(10) copies/mL), respectively. Furthermore, in a statistically significant percentage of CRF02-harboring samples, NucliSens produced viral load values undetectable or 1 log(10) lower than those obtained in Versant and Amplicor assays. Altogether, these data underline a low performance of NucliSens in detecting and quantifying viremia in plasma samples harboring the CRF02. These results are potentially important as global distribution of new HIV-1 subtypes is expanding, and recombinant strains, particularly CRF02, are emerging and becoming highly prevalent.
引用
收藏
页码:488 / 494
页数:7
相关论文
共 50 条
  • [1] Most HIV-1 genetic subtypes have entered Sweden
    Alaeus, A
    Leitner, T
    Lidman, K
    Albert, J
    [J]. AIDS, 1997, 11 (02) : 199 - 202
  • [2] Subtype-specific problems with quantification of plasma HIV-1 RNA
    Alaeus, A
    Lidman, K
    Sonnerborg, A
    Albert, J
    [J]. AIDS, 1997, 11 (07) : 859 - 865
  • [3] Balotta C, 2001, J ACQ IMMUN DEF SYND, V27, P499, DOI 10.1097/00126334-200108150-00012
  • [4] COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1995, 346 (8982): : 1085 - 1087
  • [5] DETECTION OF DIVERSE HIV-1 GENETIC SUBTYPES IN THE USA
    BRODINE, SK
    MASCOLA, JR
    WEISS, PJ
    ITO, SI
    PORTER, KR
    ARTENSTEIN, AW
    GARLAND, FC
    MCCUTCHAN, FE
    BURKE, DS
    [J]. LANCET, 1995, 346 (8984): : 1198 - 1199
  • [6] CARR J, 1999, HUMAN RETROVIRUS A 3
  • [7] Full genome sequences of human immunodeficiency virus type 1 subtypes G and A/G intersubtype recombinants
    Carr, JK
    Salminen, MO
    Albert, J
    Sanders-Buell, E
    Gotte, D
    Birx, DL
    McCutchan, FE
    [J]. VIROLOGY, 1998, 247 (01) : 22 - 31
  • [8] CDC, 2001, Morbidity and Mortality Weekly Report, V50, P1
  • [9] Diverse HIV-1 genetic subtypes in UK
    Clewley, JP
    Arnold, C
    Barlow, KL
    Grant, PR
    Parry, JV
    [J]. LANCET, 1996, 347 (9013) : 1487 - 1487
  • [10] HIV-1 subtypes and plasma RNA quantification
    Damond, F
    Apetrei, C
    Descamps, D
    Brun-Vézinet, F
    Simon, F
    [J]. AIDS, 1999, 13 (02) : 286 - 288