Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: In vivo fluoroscopic analysis during activities of daily living

被引:101
作者
Fantozzi, Silvia
Catani, Fabio
Ensini, Andrea
Leardini, Alberto
Giannini, Sandro
机构
[1] Univ Bologna, Dept Elect Comp Sci & Syst, I-40136 Bologna, Italy
[2] Ist Ortopedici Rizzolo, Movement Anal Lab, I-40136 Bologna, Italy
[3] Ist Ortopedici Rizzolo, Dept Orthopaed Surg, I-40136 Bologna, Italy
关键词
total knee replacement; femoral roll back; fluoroscopy analysis; cruciate retaining; posterior stabilized;
D O I
10.1002/jor.20306
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Restoration of the physiological flexor/extensor mechanism at the knee in terms of appropriate muscular lever arms, proper required quadriceps force, and suitable patellofemoral compressive force, is fundamental for the success of total knee replacement. Therefore, measurements of anteroposterior translation of the femoral component over the tibial base-plate against joint flexion during daily living activities are essential for the assessment of the in vivo performance of current prosthesis designs. Patients treated with posterior stabilized and cruciate retaining prostheses with excellent clinical scores were evaluated during stair climbing, sitting and rising from a chair, and step up and down, using a three-dimensional pose reconstruction technique based on videofluoroscopy. The posterior stabilized patients experienced a fairly consistent and physiological rollback specific of each motor task, demonstrating proper function of the spine-cam mechanism. Rollback was somehow inconsistent among subjects in the cruciate retaining group, accompanied with a smaller range of knee flexion. In this group, more posterior locations of the condyles correlated significantly with higher clinical and functional scores. Articular surface conformity restores physiological rollback in the presence of a spine-cam mechanism, but not coherently in the presence of the posterior cruciate ligament. (c) 2006 Orthopaedic Research Society.
引用
收藏
页码:2222 / 2229
页数:8
相关论文
共 16 条
[1]
Ahlback S., 1968, Acta Radiol Diagn (Stockh), V277, P7
[2]
The use of functional analysis in evaluating knee kinematics [J].
Andriacchi, TP ;
Dyrby, CO ;
Johnson, TS .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :44-53
[3]
Banks S A, 1997, Am J Knee Surg, V10, P261
[4]
In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[5]
Implant design affects knee arthroplasty kinematics during stair-stepping [J].
Banks, SA ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) :187-193
[6]
Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy [J].
Banks, SA ;
Hodge, WA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) :638-649
[7]
Patellofemoral forces after total knee arthroplasty: effect of extensor moment arm [J].
Browne, C ;
Hermida, JC ;
Bergula, A ;
Colwell, CW ;
D'Lima, DD .
KNEE, 2005, 12 (02) :81-88
[8]
The influence of femoral rollback on patellofemoral contact loads in total knee arthroplasty [J].
Churchill, DL ;
Incavo, SJ ;
Johnson, CC ;
Beynnon, BD .
JOURNAL OF ARTHROPLASTY, 2001, 16 (07) :909-918
[9]
Multicenter determination of in vivo kinematics after total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR ;
Haas, BD ;
Stiehl, JB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) :37-57
[10]
In vivo fluoroscopic analysis of fixed-bearing total knee replacements [J].
Dennis, DA ;
Komistek, RD ;
Mahfouz, MR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :114-130