In vivo fluoroscopic analysis of fixed-bearing total knee replacements

被引:140
作者
Dennis, DA
Komistek, RD
Mahfouz, MR
机构
[1] Rocky Mt Musculoskeletal Res Lab, Denver, CO USA
[2] Colorado Sch Mines, Div Engn, Golden, CO 80401 USA
关键词
D O I
10.1097/01.blo.0000062385.79828.72
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In vivo kinematic patterns were determined for subjects (patients participating in the study), having either a fixed-bearing posterior-stabilized or posterior cruciate-retaining total knee arthroplasty. While under fluoroscopic surveillance, subjects did normal gait and a deep knee bend. Video images were downloaded to a workstation computer and analyzed in three dimensions using an iterative model-fitting approach. Femorotibial contact paths for the medial and lateral condyles, axial rotation, and condylar lift-off were determined. During a deep knee bend, subjects having a posterior-stabilized total knee arthroplasty routinely experienced posterior femoral rollback of their lateral condyle and normal axial rotational patterns, whereas random subjects having a posterior cruciate-retaining total knee arthroplasty experienced paradoxical anterior sliding and opposite axial rotational patterns. During gait, posterior-stabilized and posterior cruciate-retaining total knee arthroplasties experienced similar kinematic patterns, with the presence of paradoxical sliding and opposite axial rotational patterns. Subjects having posterior-stabilized and posterior cruciate-retaining total knee arthroplasties experienced condylar lift-off. Subjects having a posterior cruciate-retaining total knee arthroplasty predominantly experienced lateral condylar lift-off whereas subjects with posterior-stabilized total knee arthroplasties experienced either medial or lateral condylar lift-off. Subjects having a posterior-stabilized total knee arthroplasty experienced significantly greater weightbearing range of motion.
引用
收藏
页码:114 / 130
页数:17
相关论文
共 46 条
[1]  
Andriacchi T P, 1986, J Arthroplasty, V1, P211, DOI 10.1016/S0883-5403(86)80033-X
[2]   FUNCTIONAL-ANALYSIS OF PRE-KNEE AND POST-KNEE SURGERY - TOTAL KNEE ARTHROPLASTY AND ACL RECONSTRUCTION [J].
ANDRIACCHI, TP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :575-581
[3]  
ANDRIACCHI TP, 1994, JAMA-J AM MED ASSOC, V271, P1349
[4]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[5]   PERFORMANCE OF THE TIBIAL COMPONENT IN TOTAL KNEE REPLACEMENT - CONVENTIONAL AND REVISION DESIGNS [J].
BARTEL, DL ;
BURSTEIN, AH ;
SANTAVICCA, EA ;
INSALL, JN .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07) :1026-1033
[6]   In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate-retaining total knee arthroplasty [J].
Bertin, KC ;
Komistek, RD ;
Dennis, DA ;
Hoff, WA ;
Anderson, DT ;
Langer, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (08) :1040-1048
[7]  
BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
[8]   USE OF THE QUADRICEPS ACTIVE TEST TO DIAGNOSE POSTERIOR CRUCIATE-LIGAMENT DISRUPTION AND MEASURE POSTERIOR LAXITY OF THE KNEE [J].
DANIEL, DM ;
STONE, ML ;
BARNETT, P ;
SACHS, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (03) :386-391
[9]   Femoral condylar lift-off in vivo in total knee arthroplasty [J].
Dennis, DA ;
Komistek, RD ;
Walker, SA ;
Cheal, EJ ;
Stiehl, JB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (01) :33-39
[10]   Range of motion after total knee arthroplasty - The effect of implant design and weight-bearing conditions [J].
Dennis, DA ;
Komistek, RD ;
Stiehl, JB ;
Walker, SA ;
Dennis, KN .
JOURNAL OF ARTHROPLASTY, 1998, 13 (07) :748-752