Fluorimetric flow injection analysis of trace amount of formaldehyde in environmental atmosphere with 5,5-dimethylcyclohexane-1,3-dione

被引:51
作者
Sakai, T
Tanaka, S
Teshima, N
Yasuda, S
Ura, N
机构
[1] Aichi Inst Technol, Dept Appl Chem, Toyota 4700392, Japan
[2] Tokai Technol Ctr, Nagoya, Aichi 4650021, Japan
[3] Soma Opt, Hinode, Tokyo 1900182, Japan
关键词
sensitive flow injection analysis; formaldehyde; dimedone; fluorimetry; environmental atmosphere;
D O I
10.1016/S0039-9140(02)00200-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive flow injection method with fluorimetry and 5,5-dimethylcyclohexane-1,3-dione (dimedone) was developed for the determination of formaldehyde. Formaldehyde reacted with dimedone in the presence of ammonium acetate to form a fluorescence compound, which has an excitation wavelength at 395 mn and an emission wavelength at 463 nm. A two-channel flow system was assembled. Distilled water and 0.3% dimedone buffered at pH 5.5 were delivered at 0.7 ml min(-1) and 100 mul of sample was injected into the carrier stream. The reaction was done in the reaction system designed newly, which consists of heating and cooling devices. The chemical reactivity with formaldehyde was excellent in the reaction system and selective. The calibration graphs were linear in the range of 25100 and 5-10 ppb. RSDs (n = 10) for 50 and 10 ppb formaldehyde were 0.6 and 3.4% and the LOD (S/N= 3) was 0.9 ppb. The sample throughput was 20 h(-1). The method was applied to the determination of formaldehyde in gas sample evolved from adhesive agents and in living environmental indoor. The sensitive and selective method is useful for monitoring trace of formaldehyde in the environmental atmosphere. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1271 / 1278
页数:8
相关论文
共 18 条
[1]  
CAMERON JM, 1966, MED SCI LAW, V8, P209
[2]   CONTINUOUS AUTOMATED-DETERMINATION OF ATMOSPHERIC FORMALDEHYDE AT THE PARTS-PER-TRILLION LEVEL [J].
FAN, Q ;
DASGUPTA, PK .
ANALYTICAL CHEMISTRY, 1994, 66 (04) :551-556
[3]   Fluorometric determination of formaldehyde [J].
Girousi, ST ;
Golia, EE ;
Voulgaropoulos, AN ;
Maroulis, AJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (05) :667-668
[4]   GAS-LIQUID-CHROMATOGRAPHIC ANALYSIS OF DIMEDONE DERIVATIVES OF FORMALDEHYDE AND OTHER ALIPHATIC-ALDEHYDES ON CAPILLARY COLUMNS [J].
JANOS, E ;
BALLA, J ;
TYIHAK, E ;
GABORJANYI, R .
JOURNAL OF CHROMATOGRAPHY, 1980, 191 (APR) :239-244
[5]  
*JIS, 1993, K0303 JIS JAP STAND
[6]   Measurement of atmospheric formaldehyde with a diffusion scrubber and light-emitting diode-liquid-core waveguide based fluorometry [J].
Li, JZ ;
Dasgupta, PK ;
Genfa, Z ;
Hutterli, MA .
FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 2001, 5 (1-2) :2-12
[7]  
*MIN HLTH JAP, 1997, REP MIN ASS CHEM SUB
[8]   TRACE ANALYSIS OF ALDEHYDES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND PRECOLUMN FLUORIGENIC LABELING WITH 5,5-DIMETHYL-1,3-CYCLOHEXANEDIONE [J].
MOPPER, K ;
STAHOVEC, WL ;
JOHNSON, L .
JOURNAL OF CHROMATOGRAPHY, 1983, 256 (02) :243-252
[9]  
*NIH, 1980, NAT CANC I TECHN REP, P194
[10]  
NISHIKAWA H, 1987, BUNSEKI KAGAKU, V36, P381