An investigation of factors affecting detector and geometric correction in normalization of 3-D PET data

被引:30
作者
Bailey, DL [1 ]
Townsend, DW [1 ]
Kinahan, PE [1 ]
Grootoonk, S [1 ]
Jones, T [1 ]
机构
[1] UNIV PITTSBURGH, MED CTR, PET FACIL, PITTSBURGH, PA 15213 USA
关键词
D O I
10.1109/23.552739
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Normalization in three-dimensional (3-D) positron emission tomography (PET) comprises two aspects: correction for differential detector response and correction for geometric effects, Comparison of rotating rod source and uniform cylinder data suggests that the position of the source used to correct for sensitivity should be similar to that of the emission data, A plane source method has been devised that uses a moving line source that traverses the transaxial field-of-view, emulating a plane source, but without the problems associated with using a conventional plane source in 3-D (uniformity, scatter, cost, etc), This device has been used to record high count density acquisitions for direct normalization of emission data and alsb to examine geometric effects with increasing azimuthal (o) and polar (theta) angles in the 3-D data set, The data have confirmed observations of two distinct geometric patterns seen previously in two-dimensional PET: an overall transaxial sensitivity profile that decreases toward the center of the projection and a crystal interference profile that changes, with position in the block, Correction for the first geometric component removes a low-sensitivity ''hole'' in 3-D PET reconstructions, and correction for the second component removes ''ring'' artifacts, The direct normalization approach produces an artifact along the central axis of the scanner, A quantitative index of nonuniformity for 1-pixel-thick annular regions of interest showed a reduction from 60% nonuniformity with no corrections to less than 15% when the plane source data were used to directly normalize the emission data, The moving line source provides high quality data and mag be an appropriate normalization device for 3-D PET.
引用
收藏
页码:3300 / 3307
页数:8
相关论文
共 21 条
[1]   A CONVOLUTION-SUBTRACTION SCATTER CORRECTION METHOD FOR 3D PET [J].
BAILEY, DL ;
MEIKLE, SR .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) :411-424
[2]   NOISE EQUIVALENT COUNT MEASUREMENTS IN A NEURO-PET SCANNER WITH RETRACTABLE SEPTA [J].
BAILEY, DL ;
JONES, T ;
SPINKS, TJ ;
GILARDI, MC ;
TOWNSEND, DW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :256-260
[3]  
BAILEY DL, 1993, INT CONGR SER, V1030, P341
[4]  
BAILEY DL, 1995, J NUCL MED, V36
[5]   OBJECT SHAPE DEPENDENT SCATTER SIMULATIONS FOR PET [J].
BARNEY, JS ;
ROGERS, JG ;
HARROP, R ;
HOVERATH, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :719-725
[6]   A PROCEDURE FOR CALIBRATING AND CORRECTING DATA TO ACHIEVE ACCURATE QUANTITATIVE VALUES IN POSITRON EMISSION TOMOGRAPHY [J].
BERGSTROM, M ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G ;
GREITZ, T ;
LITTON, J ;
WIDEN, L .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :555-557
[7]   QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .7. A TECHNIQUE TO REDUCE NOISE IN ACCIDENTAL COINCIDENCE MEASUREMENTS AND COINCIDENCE EFFICIENCY CALIBRATION [J].
CASEY, ME ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :845-850
[8]  
CHERRY SR, 1993, J NUCL MED, V34, P671
[9]   3D PET USING A CONVENTIONAL MULTISLICE TOMOGRAPH WITHOUT SEPTA [J].
CHERRY, SR ;
DAHLBOM, M ;
HOFFMAN, EJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) :655-668
[10]   CALIBRATION OF DETECTOR SENSITIVITY IN POSITRON CAMERAS [J].
CHESLER, DA ;
STEARNS, CW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :768-772