Separation and identification of organic acid-coenzyme A thioesters using liquid chromatography/electrospray ionization-mass spectrometry

被引:36
作者
Dalluge, JJ [1 ]
Gort, S [1 ]
Hobson, R [1 ]
Selifonova, O [1 ]
Amore, F [1 ]
Gokarn, R [1 ]
机构
[1] Cargill Cent Res, Minneapolis, MN 55440 USA
关键词
liquid chromatography/mass spectrometry; liquid chromatography/tandem mass spectrometry; metabolite; metabolomics; metabolic engineering;
D O I
10.1007/s00216-002-1554-x
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method has been developed for the direct determination of coenzyme A (CoA) and organic acid-CoA thioesters in mixtures using directly combined liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). Mixtures of CoA and organic acid-CoA thioesters were analyzed by LC/ESI-MS with detection of protonated molecular ions and characteristic fragment ions for each compound. The identities of the CoA-thioesters were established based on LC retention times and simultaneously recorded mass spectra. Monitoring of the CoA specific fragment ion at m/z 428 throughout the chromatogram provides a unique fingerprint for CoA content in the samples that corroborates the identification of organic acid-CoA thioesters in the mixtures. Furthermore, fragment ions arising from the ester link-age portion of the molecule allow unambiguous identification of the CoA esters in the samples. A second LC elution system was developed that allows the simultaneous separation and identification of 2-hydroxypropionyl-CoA (lactyl-CoA) and 3-hydroxypropionyl CoA (3HP-CoA), which have the same mass and identical MS fragmentation behavior. The utility of LC/ESI-MS employing this elution system is demonstrated by the determination of 3HP-CoA and lactyl-CoA (converted to CoA-thioesters from their corresponding free acids using CoA-transferase) in fermentation broths from Escherichia coli strains engineered for the production of 3-hydroxypropionic acid (3HP) External calibration employing a purified 3HP-CoA standard allowed indirect quantification of 3HP content in the broth with a precision of 1% (RSD). The feasibility of extending the method described above to perform LC/selected reaction monitoring-tandem mass spectrometry for direct determination of organic acid-CoA thioesters in cells was also demonstrated.
引用
收藏
页码:835 / 840
页数:6
相关论文
共 8 条
[1]   Quantification of intracellular metabolites in Escherichia coli K12 using liquid chromatographic-electrospray ionization tandem mass spectrometric techniques [J].
Buchholz, A ;
Takors, R ;
Wandrey, C .
ANALYTICAL BIOCHEMISTRY, 2001, 295 (02) :129-137
[2]  
JACKOWSKI S, 1996, ESCHERICHIA COLI SAL, V1, P687
[3]   SEPARATION AND MEASUREMENT OF SHORT-CHAIN COENZYME-A COMPOUNDS IN RAT-LIVER BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KING, MT ;
REISS, PD .
ANALYTICAL BIOCHEMISTRY, 1985, 146 (01) :173-179
[4]  
Lee C.-Y., 1982, The Pyridine Nucleotide Coenzymes, P189, DOI 10.1016/b978-0-12-244750-1.50015-4
[5]   COMBINED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC CONTINUOUS-FLOW FAST ATOM BOMBARDMENT MASS-SPECTROMETRIC ANALYSIS OF ACYLCOENZYME-A COMPOUNDS [J].
NORWOOD, DL ;
BUS, CA ;
MILLINGTON, DS .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (02) :289-301
[6]  
PATEL SS, 1987, J BIOL CHEM, V262, P7132
[7]  
SELMER T, 2002, EUR J BIOCHEM, V269, P1
[8]  
VALENTIN HE, 1994, APPL MICROBIOL BIOT, V40, P699