The frequency-dependent directivity of a planar Fabry-Perot polymer film ultrasound sensor

被引:58
作者
Cox, Benjamin T. [1 ]
Beard, Paul C. [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1109/TUFFC.2007.253
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A model of the frequency-dependent directivity of a planar, optically-addressed, Fabry-Perot (FP), polymer film ultrasound sensor is described and validated against experimental directivity measurements made over a frequency range of 1 to 15 MHz and angles from normal incidence to 80 degrees. The model may be used, for example, as a predictive tool to improve sensor design, or to provide a noise-free response function that could be deconvolved from sound-field measurements in order to improve accuracy in high-frequency metrology and imaging applications. The specific question of whether effective element sizes as small as the optical-diffraction limit can be achieved was investigated. For a polymer film sensor with a FP cavity of thickness d, the minimum effective element radius was found to be about 0.9d, and that an illumination spot radius of less than d/4 is required to achieve it.
引用
收藏
页码:394 / 404
页数:11
相关论文
共 26 条
[1]   Toward virtual biopsy through an all fiber optic ultrasonic miniaturized transducer: A proposal [J].
Acquafresca, A ;
Biagi, E ;
Masotti, L ;
Menichelli, D .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (10) :1325-1335
[2]  
ASKENAZI S, 2005, P SOC PHOTO-OPT INS, V5697, P243
[3]   Two-dimensional ultrasound receive army using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging [J].
Beard, PC .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (06) :1002-1012
[4]   Interrogation of free-space Fabry-Perot sensing interferometers by angle tuning [J].
Beard, PC .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) :1998-2005
[5]   Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones [J].
Beard, PC ;
Hurrell, AM ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :256-264
[6]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[7]  
BEARD PC, 1994, P SOC PHOTO-OPT INS, V2331, P112
[8]  
Brekhovskikh L.M., 1998, ACOUSTICS LAYERED ME
[9]   Fabry Perot polymer film fibre-optic hydrophones and arrays for ultrasound field characterisation [J].
Cox, BT ;
Zhang, EZ ;
Laufer, JG ;
Beard, PC .
AMUM 2004: ADVANCED METROLOGY FOR ULTRASOUND IN MEDICINE 2004, 2004, 1 :32-37
[10]   Fast calculation of pulsed photoacoustic fields in fluids using k-space methods [J].
Cox, BT ;
Beard, PC .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 117 (06) :3616-3627