Solid-phase extraction system for Pb (II) ions enrichment based on multiwall carbon nanotubes coupled on-line to flame atomic absorption spectrometry

被引:153
作者
Francisco Barbosa, Adriano
Gava Segatelli, Mariana
Cesar Pereira, Arnaldo
de Santana Santos, Antonio
Tatsuo Kubota, Lauro
Orival Luccas, Pedro
Ricardo Teixeira Tarley, Cesar [1 ]
机构
[1] Unifal, Dept Ciencias Exatas, BR-37130000 Alfenas, MG, Brazil
[2] Univ Estadual Campinas, Inst Quim, Dept Quim Inorgan, BR-13083970 Campinas, SP, Brazil
[3] Univ Estadual Campinas, Inst Quim, Dept Quim Analit, BR-13083970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
multiwall carbon nanotubes; on-line preconcentration; lead; FAAS; multivariated optimization;
D O I
10.1016/j.talanta.2006.07.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper proposes the application of multiwall carbon nanotubes (MWCNTs) as a solid sorbent for lead preconcentration using a flow system coupled to flame atomic absorption spectrometry. The method comprises the preconcentration of Pb (II) ions at a buffered solution (pH 4.7) onto 30 mg of MWCNTs previously oxidized with concentrated HNO3. The elution step is carried out with 1.0 mol L-1 HNO3. The effect of the experimental parameters, including sample pH, sampling flow rate, buffer and eluent concentrations were investigated by means of a 24 full factorial design, while for the final optimization a Doehlert design was employed. Under the best experimental conditions the preconcentration system provided detection and quantification limits of 2.6 and 8.6 mu g L-1, respectively. A wide linear range varying from 8.6 up to 775 mu g L-1 (r > 0.999) and the respective precision (relative standard deviation) of 7.7 and 1.4% for the 15 and 200 mu g L-1 levels were obtained. The characteristics obtained for the performance of the flow preconcentration system were a preconcentration factor of 44.2, preconcentration efficiency of 11 min(-1), consumptive index of 0.45 mL and sampling frequency estimated as 14 h(-1). Preconcentration studies of Pb (II) ions in the presence of the majority foreign ions tested did not show interference, attesting the good performance of MWCNTs. The accuracy of the method was assessed from analysis of water samples (tap, mineral, physiological serum and synthetic seawater) and common medicinal herbs submitted to the acid decomposition (garlic and Ginkgo Biloba). The satisfactory recovery values obtained without using analyte addition method confirms the feasibility of this method for Pb (Ii) ions determination in different type of samples. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1512 / 1519
页数:8
相关论文
共 36 条
[1]   Preconcentration procedure using cloud point extraction in the presence of electrolyte for cadmium determination by flame atomic absorption spectrometry [J].
Coelho, LM ;
Arruda, MAZ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) :743-748
[2]   Development of a new system for the speciation of chromium in natural waters and human urine samples by combining ion exchange and ETA-AAS [J].
Cordero, MTS ;
Alonso, EIV ;
de Torres, AG ;
Pavón, JMC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (03) :398-403
[3]   ONLINE SORBENT EXTRACTION, PRECONCENTRATION AND DETERMINATION OF LEAD BY ATOMIC-ABSORPTION SPECTROMETRY [J].
DEPENA, YP ;
GALLEGO, M ;
VALCARCEL, M .
TALANTA, 1995, 42 (02) :211-218
[4]   Storage of hydrogen in single-walled carbon nanotubes [J].
Dillon, AC ;
Jones, KM ;
Bekkedahl, TA ;
Kiang, CH ;
Bethune, DS ;
Heben, MJ .
NATURE, 1997, 386 (6623) :377-379
[5]   Determination of rare and rare earth elements in soils and sediments by ICP-MS using Ti(OH)4-Fe(OH)3 co-precipitation preconcentration [J].
Duan, TC ;
Chen, HT ;
Zeng, XJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (04) :410-413
[6]   Flow injection solid phase extraction with Chromosorb 102:: determination of lead in soil and waters by flame atomic absorption spectrometry [J].
Elçi, L ;
Arslan, Z ;
Tyson, JF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :1109-1116
[7]  
FANG Z, 1987, ANAL CHIM ACTA, V35, P200
[8]   Use of factorial design and Doehlert matrix for multivariate optimisation of an on-line preconcentration system for lead determination by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
dos Santos, WNL ;
Bezerra, MA ;
Lemos, VA ;
Bosque-Sendra, JM .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (05) :443-449
[9]   An automated on-line flow system for the pre-concentration and determination of lead by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
Lemos, VA ;
Santelli, RE ;
Ganzarolli, E ;
Curtius, AJ .
MICROCHEMICAL JOURNAL, 2001, 68 (01) :41-46
[10]   Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials [J].
Fisher, A ;
Goodall, PS ;
Hinds, MW ;
Nelms, SM ;
Penny, DM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (12) :1497-1528