Measurement and prediction of air movement through doorways in refrigerated rooms

被引:65
作者
Foster, AM
Barrett, R
James, SJ
Swain, MJ
机构
[1] Univ Bristol, FRPERC, Bristol BS40 5DU, Avon, England
[2] Univ Bristol, Dept Aeronaut Engn, Bristol BS8 1TR, Avon, England
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2002年 / 25卷 / 08期
关键词
cold store; door; air; convection; measurement; modelling;
D O I
10.1016/S0140-7007(01)00108-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
Reducing the amount of air infiltration through the doorways of food storage rooms would improve temperature control and the overall economics of food storage. In the UK a joint government/industry supported LINK project has been set up to look at methods of reducing air infiltration. The project is combining direct experimental measurement with computational fluid dynamics (CFD) modelling. A CFD model of air movement through a doorway has been developed and verified against conventional and laser Doppler anemometry (LDA) measurements. The CFD model has been shown to be generally accurate, however, there are areas where the accuracy is less than perfect. For example the CFD model predicted the shape of the vertical profile accurately, although it under-predicted the maximum velocity by 0.1 m s(-1) and it predicted the height at which the airflow changed direction to be 40 mm lower than was measured by the LDA. (C) 2002 Elsevier Science Ltd and IIR. All rights reserved.
引用
收藏
页码:1102 / 1109
页数:8
相关论文
共 24 条
[1]  
Alamdari F., 1997, AIR CURTAINS COMMERC
[2]   EXPERIMENTAL-DETERMINATION OF COLD LOSS CAUSED BY OPENING INDUSTRIAL COLD-ROOM DOORS [J].
AZZOUZ, A ;
GOSSE, J ;
DUMINIL, M .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (01) :57-66
[3]  
Brown WG, 1962, INT J HEAT MASS TRAN, V5, P859, DOI DOI 10.1016/0017-9310(62)90184-9
[4]  
CHEN P, 1999, P 20 INT C REFR SYDN
[5]  
Emswiler J. E., 1926, ASHRAE T, V32, P1
[6]  
Fritzsche C., 1968, KALTETECHNIK KLIMATI, V20, P279
[7]  
Gosney W.B., 1975, P I REFRIG, V72, P31
[8]  
Hendrix W. A., 1989, ASHRAE T, V95, P1158
[9]   Analysis of the air flow in a cold store by means of computational fluid dynamics [J].
Hoang, ML ;
Verboven, P ;
De Baerdemaeker, J ;
Nicolaï, BM .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2000, 23 (02) :127-140
[10]   Effect of fluctuation in inlet airflow temperature on CFD simulation of air-blast chilling process [J].
Hu, ZH ;
Sun, DW .
JOURNAL OF FOOD ENGINEERING, 2001, 48 (04) :311-316