Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure

被引:183
作者
Agarwal, Rajiv
Peixoto, Aldo J.
Santos, Sergio F. F.
Zoccali, Carmine
机构
[1] Richard L Roudebush VAMC, Indianapolis, IN 46202 USA
[2] Indiana Univ, Sch Med, Div Nephrol, Dept Med, Indianapolis, IN 46204 USA
[3] Yale Univ, Nephrol Sect, Dept Med, Sch Med, New Haven, CT USA
[4] VA Connecticut Healthcare Syst, West Haven, CT USA
[5] Univ Estado Rio De Janeiro, Div Nephrol, Dept Med, Rio De Janeiro, Brazil
[6] Riuniti Hosp, CNR, IBIM Clin Epidemiol Renal Dis & Hypertens, Reggio Di Calabria, Italy
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2006年 / 1卷 / 03期
关键词
D O I
10.2215/CJN.01891105
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
BP readings that are obtained in the dialysis unit are commonly used to make therapeutic decisions by clinicians and to predict morbidity and mortality by epidemiologists. Dialysis unit BP are also incorporated in the recent guidelines to target BP control. The magnitude of the difference, overestimation or underestimation, and agreement between dialysis unit BP and ambulatory BP (ABP) are unknown. Articles were selected from Medline to identify those that reported both ABP and dialysis unit BP in hemodialysis patients. Bias was calculated as the difference between dialysis unit and the corresponding ABP. Agreement limits between the BP measurement techniques were assessed by pooled SD of the difference using Bland-Altman methods. Predialysis systolic BP generally overestimated ABP by a variable amount. The heterogeneity between BP measurements did not allow for pooling of the estimates. The agreement limits between the two BP was 41.7 to -25.2 mmHg. Predialysis diastolic BP also generally overestimated the ABP with wide agreement limits (23.7 to -18.9 mmHg). In contrast, postdialysis BP underestimated average ABP with wide agreement limits for both postdialysis systolic BP (33.1 to -36.3 mmHg) and diastolic BP (19.3 to -23.9 mmHg). Dialysis unit BP measurements are imprecise estimates of ABP. Better methods are needed for the assessment of BP in hemodialysis patients for clinical decision making.
引用
收藏
页码:389 / 398
页数:10
相关论文
共 48 条
[11]   Prognostic value of ambulatory blood-pressure recordings in patients with treated hypertension [J].
Clement, DL ;
De Buyzere, ML ;
De Bacquer, DA ;
de Leeuw, PW ;
Duprez, DA ;
Fagard, RH ;
Gheeraert, PJ ;
Missault, LH ;
Braun, JJ ;
Six, RO ;
Van Der Niepen, P ;
O'Brien, E .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 348 (24) :2407-2415
[12]   Normalization of hematocrit in hemodialysis patients with cardiac disease does not increase blood pressure [J].
Conlon, PJ ;
Kovalik, E ;
Schumm, D ;
Minda, S ;
Schwab, SJ .
RENAL FAILURE, 2000, 22 (04) :435-444
[13]  
Conlon PJ, 1996, J AM SOC NEPHROL, V7, P2658
[14]   Ambulatory blood pressure monitoring in dialysis patients and estimation of mean interdialytic blood pressure [J].
Coomer, RW ;
Schulman, G ;
Breyer, JA ;
Shyr, Y .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1997, 29 (05) :678-684
[15]  
Covic A, 1996, CONTRIB NEPHROL, V119, P157
[16]   Superiority of ambulatory over clinic blood pressure measurement in predicting mortality - The Dublin Outcome Study [J].
Dolan, E ;
Stanton, A ;
Thijs, L ;
Hinedi, K ;
Atkins, N ;
McClory, S ;
Den Hond, E ;
McCormack, P ;
Staessen, JA ;
O'Brien, E .
HYPERTENSION, 2005, 46 (01) :156-161
[17]  
Elisaf M, 1996, J HUM HYPERTENS, V10, pS43
[18]   Relationship of ambulatory blood pressure monitoring data to echocardiographic findings in haemodialysis patients [J].
Erturk, S ;
Ertug, AE ;
Ates, K ;
Duman, N ;
Aslan, SM ;
Nergisoglu, G ;
Diker, E ;
Erol, C ;
Karatan, O ;
Erbay, B .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1996, 11 (10) :2050-2054
[19]   Relationship between ambulatory blood pressure and follow-up clinic blood pressure in elderly patients with systolic hypertension [J].
Fagard, RH ;
Staessen, JA ;
Thijs, L ;
Bulpitt, CJ ;
Clement, D ;
de Leeuw, PW ;
Jääskivi, M ;
Mancia, G ;
O'Brien, E ;
Palatini, P ;
Tuomilehto, J ;
Webster, J .
JOURNAL OF HYPERTENSION, 2004, 22 (01) :81-87
[20]   Blunted nocturnal blood pressure decrease and left-ventricular mass in hypertensive hemodialysis patients [J].
Faguglia, RM ;
Quintaliani, G ;
Pasini, P ;
Ciao, G ;
Cicconi, B ;
Pasticci, F ;
Buoncristiani, U .
NEPHRON, 2002, 91 (01) :79-85