Supersonic jet/multiphoton ionization/mass spectrometry of dioxins formed by the thermal reaction of phenols in the absence and presence of an FeCl3 catalyst

被引:31
作者
Uchimura, T [1 ]
Imasaka, T [1 ]
机构
[1] Kyushu Univ, Fac Engn, Dept Chem Sci & Technol, Fukuoka 8128581, Japan
关键词
D O I
10.1021/ac000021b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dioxins, which are thermally produced from several precursor molecules, were investigated by supersonic jet/multiphoton ionization/time-of-flight mass spectrometry (SSJ/MPI/TOF-MS). Dibenzofuran and dibenzo-p-dioxin were efficiently generated from o-chlorophenol and also from phenol after a chlorination reaction with FeCl3. The present technique was employed for the continuous monitoring of a specified isomer, e,g,, m-chlorophenol, which is formed at relatively low temperatures by chlorination of phenol with FeCl3, A dimerization reaction that forms a dibenzo-p-dioxin, e.g,, dichlorodibenzo-p-dioxin from 2,4-dichlorophenol, at relatively high temperatures was also investigated. The number of chlorine atoms in the dioxin molecule was largely correlated with the number of chlorine atoms in the precursor molecule. However, some unexpected compounds, which probably occur by dechlorination and rearrangement reactions, were also found. Thus, the SSJ/MPI/TOF-MS technique represents a sensitive, as well as selective, analytical method for monitoring thermally generated dioxins.
引用
收藏
页码:2648 / 2652
页数:5
相关论文
共 22 条
[11]   SYNTHESIS AND IDENTIFICATION OF THE 22 TETRACHLORODIBENZO-PARA-DIOXIN ISOMERS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND GAS-CHROMATOGRAPHY [J].
NESTRICK, TJ ;
LAMPARSKI, LL ;
STEHL, RH .
ANALYTICAL CHEMISTRY, 1979, 51 (13) :2273-2281
[12]  
ONODA T, UNPUB ANAL CHIM ACTA
[13]   Continuous monitoring of ultratrace products of incomplete combustion during incineration with a novel mobile Jet-REMPI device [J].
Oser, H ;
Thanner, R ;
Grotheer, HH .
CHEMOSPHERE, 1998, 37 (9-12) :2361-2374
[14]   Atmospheric pressure laser ionization. An analytical technique for highly selective detection of ultralow concentrations in the gas phase [J].
Schmidt, S ;
Appel, MF ;
Garnica, RM ;
Schindler, RN ;
Benter, T .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3721-3729
[15]   APPLICABILITY OF RESONANT 2-PHOTON IONIZATION IN SUPERSONIC BEAM MASS-SPECTROMETRY TO HALOGENATED AROMATIC-HYDROCARBONS [J].
TEMBREULL, R ;
SIN, CH ;
LI, P ;
PANG, HM ;
LUBMAN, DM .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1186-1192
[16]   LASER MASS-SPECTROMETRY OF DIBENZODIOXIN DIBENZOFURAN AND 2 ISOMERS OF DICHLORODIBENZODIOXINS - SELECTIVE IONIZATION [J].
WEICKHARDT, C ;
ZIMMERMANN, R ;
BOESL, U ;
SCHLAG, EW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (03) :183-185
[17]   ISOMER-SELECTIVE IONIZATION OF CHLORINATED AROMATICS WITH LASERS FOR ANALYTICAL TIME-OF-FLIGHT MASS-SPECTROMETRY - FIRST RESULTS FOR POLYCHLORINATED DIBENZO-P-DIOXINS (PCDD), BIPHENYLS (PCB) AND BENZENES (PCBZ) [J].
ZIMMERMANN, R ;
BOESL, U ;
WEICKHARDT, C ;
LENOIR, D ;
SCHRAMM, KW ;
KETTRUP, A ;
SCHLAG, EW .
CHEMOSPHERE, 1994, 29 (9-11) :1877-1888
[18]  
Zimmermann R, 1999, RAPID COMMUN MASS SP, V13, P307, DOI 10.1002/(SICI)1097-0231(19990315)13:5<307::AID-RCM482>3.3.CO
[19]  
2-1
[20]   THE IONIZATION ENERGIES OF POLYCHLORINATED DIBENZO-P-DIOXINS - NEW EXPERIMENTAL RESULTS AND THEORETICAL-STUDIES [J].
ZIMMERMANN, R ;
BOESL, U ;
LENOIR, D ;
KETTRUP, A ;
GREBNER, TL ;
NEUSSER, HJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 145 (1-2) :97-108